University of Patras
Ανάπτυξη αναλυτικών μεθοδολογιών για τη μελέτη βιογενών υλικών με χρήση φασματοσκοπικών τεχνικών
Abstract
dc:descriptionBiogenic materials are composites developed through a series of biological reactions(biomineralization). The term refers to both physiological and to pathological formations as well. Biogenic materials have been the subject of many and extended interdisciplinary investigations since the nineteenth century. Calcium phosphates, calcium carbonates, calcium oxalates, silicon, iron and calcium sulfate are some of the most common cases inorganic compounds of biogenic materials. Their occurrence is common in a number of organisms (shells, mollusks, plants) and in the human body (teeth, bones, urinary stones). In the present work new non-destructive methodologies were developed for the study three different classes of biogenic materials. Three different techniques were employed for the quantitative analysis of mixtures of crystalline materials; X-Ray Diffraction and two vibrational techniques (Raman Spectroscopy, Infrared Spectroscopy). In the case of calcium carbonate polymorphs (calcite, aragonite, vaterite), a nondestructive methodology based on the use of Fourier Transform Raman Spectroscopy (FT-RS), for the discrimination and the quantitative determination of the crystal phases in their ternary mixtures, was developed. Using binary mixtures from known quantities of the crystal phase the calibration curves were constructed using the Raman bands at 711cm⁻¹ for calcite, 700cm⁻¹ for aragonite and 750cm⁻¹ for vaterite. Detection limits (DL) were found to be 0.13, 0.18 and 1.3mol % for calcite, aragonite and vaterite, respectively, while the relative errors in determining the mol % of a known ternary mixture of calcium carbonate polymorphs were 1.6% for calcite, 0.3% for aragonite and 1.1% for vaterite. Similar methodology was developed using XRD. XRD calibration curves were constructed using the 104 reflection for calcite, the 221 reflection for aragonite and the 110 reflection of vaterite. Detection limits for calcite, aragonite and vaterite were found to be 0.90, 2.90, 6.90mol %, respectively, while the relative errors in determining the mol% of the same ternary mixture used for testing the FT-RS methodology were 2.5, 1.8 and 0.6%, for calcite, aragonite and vaterite, respectively. Infrared spectroscopy was used, in order to determinate the absolute concentration of the calcium carbonate crystal phases, using the bands at 714cm⁻¹ for calcite, at 700cm⁻¹ and 714cm⁻¹ for aragonite and at 745cm⁻¹ for vaterite. The asborptivities were found to be a7 1 4= 63.38 for calcite, α7 0 0= 19.30 and α7 1 4= 40.43 for aragonite and a745 =21.79 for vaterite. The detection limits were also established and found to be D.L.™ =6.6 x 10⁻⁴ for calcite, D.L.™ = 2.2 x 10⁻³ and D.L.™ = 1.1 x 10⁻³ for aragonite and D.L.™ = 1.9 x 10⁻³ for vaterite. A non-destructive analytical method based on the use of Fourier-Transform Raman Spectroscopy (FT-RS) was developed for the identification and the quantitative analysis of hydroxyapatite (HAP) and collagen (COL) in bones. A calibration curve based on the Raman spectra of known powder mixtures of HAP - COL was constructed using the Raman bands at 960cm"1 for HAP and 2937cm"1 for COL. It was found that: Ι⁹⁶⁰/Ι²⁹³⁷ = 0.46/Wc - 0.36 where Ι⁹⁶⁰ and Ι²⁹³⁷ are the relative intensities for the 960cm⁻¹ and 2937cm⁻¹ Raman bands, respectively, and Wc represents the weight fraction of collagen. The detection limit for HAP and COL was found to be 2.8wt% and 0.6wt%, respectively. The potential of using RS for an in vitro point-by-point analysis ("mapping") of bones was demonstrated successfully on an artificially de-mineralized ox femur sample. Fourier Transform Infrared Spectroscopy (FTIR) and Fourier Transform Raman Spectroscopy (FTRS) were used in order to characterize the encrusted deposits formed onto a metallic prostatic stent. A urinary stone entrapped within the lumen was also analyzed. Six different substances were detected: hydroxyapatite, struvite, calcium oxalate monohydrate, potassium urate, ammonium urate and uric acid. A combination of the two techniques was necessary for the qualitative analysis of the encrustation and the stone, since Infrared Spectroscopy cannot be used for the discrimination between potassium urate and ammonium urate, while Raman Spectroscopy cannot be used for the identification of uric salts.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Vagenas, Nikolaos
- Βαγενάς, Νικόλαος
Subjects
dc:subject × 18- Φασματοσκοπία Raman
- Βιογενή υλικά
- Ουρόλιθοι
- Φασματοσκοπία IR
- Ανθρακικό ασβέστιο
- Ανάλυση οστών
- Απατιτές
- Raman spectroscopy
- Biogenic materials
- Urinary stones
- IR spectroscopy
- Calcium carbonate
- Bones analysis
- Apatites
- Ιατρική και Επιστήμες Υγείας
- Βασική Ιατρική
- Medical and Health Sciences
- Basic Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/13491