Aristotle University Of Thessaloniki (AUTH)
Προσδιορισμός απορροφούμενων δόσεων ακτινοβολίας Χ από ακτινοδιαγνωστικές εξετάσεις κοιλίας σε παιδιά ηλικίας μέχρι 5 ετών: συσχέτιση με ανθρωπομετρικά δεδομένα
Abstract
dc:descriptionAt this study the adsorbed and the effective dose was estimated, for children up to 5 years old who made an MCU radiological examination. Using PC software, three mathematical phantoms where constructed which simulate newborn, one and five years old children. With Monte Carlo technique and registered exposure factors from 30 MCU examinations, absorbed doses where calculated for all the radiosensitive organs along with the total effective dose. With TLD dosimeters entrance dose and exit dose were measured for each child and the conversion factor from entrance dose to effective dose was estimated. Also for each child a record was kept for weight, height and age. With ultrasound examination measurement of each kidney’s three dimensions were done at 24 children. The absorbed dose depends on the selected KVp, mAs and the dimensions of the light field. The mean entrance dose of the MCU radiological examination at this essay was found to be D= 3,8 mGy for children 0,1-1,0 years old and D= 4,68 mGy for children 1-5 years old. The results are comparable with other works or techniques. The dimensions of the kidneys were measured with ultrasonography. The mean length of the large axis of the left kidney is x= 63,5 ± 10,17 mm and of the right kidney x= 60,95 ± 9,43 mm. The mean volume of the left kidneys was measured to be 28,16 cm3 and of the right kidneys 28,09 cm3. Significantly statistical difference between the length and the volume of left and right kidney and between the kidney length of male and female patients was not found. The results are comparable with other works. It is not possible to define a specific mathematical formula that connects the children entrance doses with their physical characteristics. This is due to the fact that TLD dosimeters apart from the radiological entrance dose at the skin of the child, also recorded fluoroscopic dose, which was independent of age and physical dimensions of the child. The absorbed doses at the inner body organs are greater for children with large physical dimensions. This is due to greater exposure factors and to larger entrance dose which receive the child. The entrance dose to effective dose conversion factors are decrease with age. The conversion factors for newborn are twofold compared with the conversion factors of 1 year old children. The mean effective dose per film for male patient is E= 0,165 mSv and for female E= 0,162 mSv. Also among the three age groups (newborn, 1 & 5 years old) of the examined children, the mean effective doses per film are almost equal. This happens because the mean entrance dose is larger for thicker children due to larger exposure factors but the entrance dose to effective dose conversion factor is smaller. Specific actions are recommended (chapter 12) in order to reduce the absorbed dose. Besides the results from this work can be used in order to determine reference dose for the MCU radiological examination. The Monte Carlo technique and the use of mathematical phantoms is a reliable method for calculating the absorbed organ dose that the patient receives. The mathematical phantoms can also be used for estimating doses at other radiological examinations apart from MCU.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Fotakis, Michael
- Φωτάκης, Μιχαήλ
Subjects
dc:subject × 20- Παιδιατρικές ακτινολογίες εξετάσεις
- Απορροφούμενη δόση
- Μαθηματικά ομοιώματα
- Τεχνικές monte carlo
- Δοσιμετρία
- Δοσίμετρα TLD-100
- Ενεργός δόση
- Ανθρωπομετρικά δεδομένα
- Paediatric radiological examination
- Absorbed dose
- Mathematical phantoms
- Monte carlo techniques
- Dosimetry TLD-100
- Dosimetry
- Effective dose
- Anthropometric data
- Ιατρική και Επιστήμες Υγείας
- Βασική Ιατρική
- Medical and Health Sciences
- Basic Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/13987