Μελέτη των διακυμάνσεων του μικροβιακού φορτίου του αέρα νοσοκομειακών χώρων
Abstract
dc:descriptionThe practical importance and frequency of airborne nosocomial infections has been a matter of dispute for many years. This is because most of the pathogens acquired in hospitals have various ways to cause infections to patients and therefore it is very difficult or even impossible to prove that a certain infection is airborne. Although the possibility of transmission of nosocomial pathogens by air is generally accepted, the extent to which airborne infections contribute to nosocomial morbidity and mortality remains to be defined. The relative incidence of airborne infections in hospitals has been estimated to about 10%. The aim of this research was to collect qualitative and quantitative microbiological and epidemiological data concerning the bacterial load (and its fluctuations) in the air of certain hospital settings of critical importance (referring to the increased hazard for nosocomial infections). Thus, in a three years period 1752 air samplings were examined. The samplings were taken from six operating theatres (226 specimens), four intensive care units (158 specimens) and seven rooms of different clinics in the General Hospital «G. Papanikolaou». Air sampling performed by a RCS sampler (Reuter Centrifugal Impactor, Biotest, Germany), in regular intervals, so that the results could be analyzed in relation to the seasons and periods of the study. Identification of isolated bacteria was done with the Pasco ID / MIC system DIFCO and Vitek system Biomerieux at a species level, while that of fungi with conventional methods at a genes and or species level. Each air sampling from operating theatres included five specimens, one before the beginning of the day program (closed operating room) and the other four in two pairs, one during the first and one before the second operation. Each pair consisted of one specimen from the surgical field and the other from the peripheral area. This method was followed in order to determine the relative incidence of usage to the air bacterial load of the theatre. Regarding the ICUs and the patient rooms, air sampling was performed in pairs, before and after morning cleaning, including all the activities, aiming at reporting the fluctuations of air bacterial load in the rooms, in relation to their functional schedule. Moreover, the correlation of these fluctuations between different operating rooms, ICUs and wards, was evaluated in order to get a rough mapping of concrete hospital sites, concerning their microbial load. All air sample cultures from operating theatres (except for 90 specimens), intensive care units and various patient rooms were positive, with more frequent the isolation of Staphylococcus and fungi and a very limited incidence of gram-negative rods in every site. The most remarkable finding was the high isolation frequency of co-agulase negative staphylococcus (CNS), (S. epidermidis, S. hominis, S. haemalyticus, S. Cohnii, S. warneri), usually in high concentrations, in all the air samples examined. S. aureus was more frequently recovered from ICU air cultures (54,4%) compared to operating suite (31,8%) and wards ones (36,3%), while St. viridans was isolated in relatively limited percentage and low counts. Most of the gram-negative bacteria found, belonged to the Acinetobacter genus. Fungi occurred more frequently in most air samples were of genus Aspergillus, Penicillium and Alternaria. The isolated bacterial strains exhibited an intermediate resistance to broadly used antibiotics and a lower resistance comparatively to that of bacteria derived from clinical specimens, during the same period. The highest resistance was reported in ICU air bacteria, resulting to an increase of the average. In general, there was no correlation found between the fluctuations of the microbial and fungal air counts in all hospital sites with regard to the seasons of the year (P > 0,05, Kruskall - Wallis). Most operating rooms included in the study, were in accordance with the international guidelines concerning the air bacterial load in an empty operating theatre (< 70 cfu / m3), whilst an exceeding of these standards (> 180 cfu / m3) was noticed during operation, in a significant number of suites. An increase of bacterial air counts was defined in all operating theatres, with the day program progress (P < 0,001). The microbial concentration of the ambient air noticed in some of the operating rooms, was attributed to inadequacy of ventilation system, bad building substructure, heavier program and possibly to deficient keeping of cleanliness and disinfection rules. As for the ICUs and the patient rooms of various wards, microbial air counts were generally higher after the morning cleaning than before (P < 0,001), with Hematological Unit showing the highest level of clean air. During the search period, none of the isolated bacteria in the air was regarded to be the cause of any infection in patients of the same rooms, at the same time. Conclusively, it could be resumed that microbial and fungal air concentration in concrete hospital sites is not usually related to the incidence of nosocomial infections especially in wards, where routine bacterial air count determination could not be considered as a significant practice. On the contrary, critical hospital sites, such as operating facilities and special care units, where low bacterial concentration in the air is an urgent necessity, periodical air sampling is mandatory, for it essentially contributes to a reliable control of ventilation system adequate performance (filter sufficiency and integrity as well as air flow velocity and direction). Additionally, environmental air sampling is useful for investigating hospital outbreaks of infection with a known organism as well as for teaching and research purposes. In recent years, most preventive measures have concentrated in nosocomial gram- negative bacteria, which apart from certain exceptions, are transmitted by direct contact and not via air. Thus, it appears that the possibility of direct or indirect transmission of hospital pathogens (mostly gram positive bacteria and fungi) through the air has been underestimated. When other routs of hospital infections are well controlled, airborne infections may gain more practical importance in hospitals.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tsorlini, Eleni
- Τσορλίνη-Χριστοφορίδη, Ελένη
Subjects
dc:subject × 8Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/14055