Aristotle University Of Thessaloniki (AUTH)
Αριθμητικό μοντέλο πρόβλεψης πεδίων θερμοκρασίας και χημικά απαιτούμενου οξυγόνου (COD) σε αναερόβια δεξαμενή λυμάτων. Εφαρμογή στη βελτιστοποίηση σχεδιασμού
Abstract
dc:descriptionThe objectives of this thesis was to develop a three dimensional (3-D) algorithm that predicts temperature and Chemical Oxygen Demand (COD) of an anaerobic pond, to calibrate and validate the mathematical model based on experimental data series collected by the candidate from a full-scale experimental anaerobic pond and finally, the utilization of the COD simulation model, as a predictive tool of the performance of modified design scenarios aiming to improve the anaerobic ponds COD removal. The computational hydrodynamic, biochemical and thermal energy model was developed on a specialized software environment of computational fluid dynamics (FLUENT), based on the numerical method of solving fluid mechanics equations according to the finite volume technique. The experimental anaerobic pond, from which data that was required for the computational model verification was collected, was a covered anaerobic pond part of a pilot-experimental station of municipal wastewater treatment with Natural Systems, designed by the National Agricultural Research Foundation (NAGREF), at Sindos in Thessaloniki, and operates since 1996. The experimental pond, which was covered with a floating cover made by geomembrane, operated on a batch flow mode supplied with pre-screened, untreated wastewater from the nearby municipal Wastewater Treatment Plant of Thessaloniki, Greece, at a flow rate of 150 m3/day. The time-dependent solution concerned a 13th month period, similar to the period of experimental data collection. Boundary conditions of the model were incorporated by external sub-programs written in C++. The pre-processor GAMBIT was employed to develop the geometric model and mesh of the pond model. Numerical simulation was validated with temperature measurements and COD sample analyses, taken from the full scale experimental plant. The experimental job required for the verification of the simulating model was to accomplish temperature measurements and COD laboratory analyses from samples taken from the pond. In the initial stage, the temperature predictive model of the covered anaerobic pond was developed and validated, since it was the necessary base, for the COD model development. Boundary conditions included: · Ηourly mean ambient air temperature, · Mean monthly soil temperature profile, · Mean daily influent wastewater temperature and · Mean daily influent wastewater velocity The mean relative error of the simulated temperature data series, in comparison to the respective measured values (out of 164 temperature values), was 9.34% that is a strongly satisfactory result. In order to support the model validity and reliability of predicting the temperature field of an anaerobic pond, the temperature model was applied on a second similar experimental anaerobic pond, part of a wastewater treatment plant with Natural Systems at Meze of France, from which operational and performance results have been presented in the bibliography. The mean relative error was low as 7%. It is thus confirmed, that the temperature simulation model of the experimental anaerobic pond, corresponds and describes well the natural process.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2004
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Karteris, Apostolos
- Καρτέρης, Απόστολος
Subjects
dc:subject × 14- Αναερόβια δεξαμενή σταθεροποίησης
- Υγρά απόβλητα
- Φυσικά συστήματα
- Υπολογιστική ρευστοδυναμική
- Αριθμητικό μοντέλο
- Anaerobic pond
- Wastewaters
- Natural systems
- Computational fluid dynamics
- Numerical models
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Πολιτικού Μηχανικού
- Engineering and Technology
- Civil Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/14655