Aristotle University Of Thessaloniki (AUTH)
Εργαστηριακή και υπολογιστική μελέτη της σεισμικής συμπεριφοράς τοιχωμάτων από οπλισμένο σκυρόδεμα επισκευασμένων και ενισχυμένων με ινοπλισμένα πολυμερή
Abstract
dc:descriptionThe present thesis assesses the effectiveness of using fibre reinforced polymers(FRPs) strenghtening reinforces concrete(R?C) structural walls that were tested to failure during a first series of tests, and were subsequently repaired, before being strengthened with FRP sheets. For this purpose an experimental programme was designed that included the repair and strengthening of eleven 1:2.5 scale wall specimens. For the repair of specimens, heavily cracked and spalled concrete was removed from the wall base, and the base region was filled with high strenght non-shrinkage mortar. Specimens were strengthened by the use of GFRP(Glass FRP) and CFRP(Carbon FRP) to enhance both flexural and shear capacity. A key parameter was the way CFRP strips added for flexural strengthening were anchored. The imposed displacements were applied at the top of the specimens in a quasi-static way until failure occured. During tests, strenght and displacement of the specimens were recorded, along with shear and flexural deformations. From the recorded response of the specimens, the change of stiffness and the dissipated energy as a function of the imposed displacement were calculated. From the recorded hysteresis loops, as well as from the calculated values of strength and deformation the effeciency of the applied repair and strengthening techniques was assessed. The flexural and shear strength of the specimens was estimated using all the available analytical models. Based on the results of the present study, it was concluded that FRPs should be used to strengthen R/C members against undersirable failure mechanisms, such as diagonal tension and compression mechanisms. If strengthening is attempted with respect to mechanisms that involve ductile inelastic response under seismic loading, such as the flexual mechanism, the characteristics of inelastic response of strengthened members are generally poorer compared to the response recorded during the initial tests. This conclusion does not apply in the case of static loads. Using currently available analytical models for strength, the failure mode of the FRP-strengthened walls(flexural failure in that case) can be satisfactorily predicted
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2005
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Antoniades, Konstantinos
- Αντωνιάδης, Κωνσταντίνος
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/14821