Back to search

National Technical University of Athens (NTUA)

Πιθανοτική ανάλυση της αξιοπιστίας και ασφάλειας λειτουργίας των απομονωμένων συστημάτων ηλεκτρικής ενέργειας

Abstract

dc:description

In this Thesis, there is a probabilistic analysis of operation reliability and security of isolated power systems which are more vulnerable due to the small number of generating units in operation and the absence of support from neighboring power systems. The main ways of increasing the system security at the stage of their operation are to use the underfrequency load shedding protection and to keep adequate emergency spinning reserve. Initially, the well known model of frequency dynamic response is presented, which is used when an imbalance between the load demand and the generation occurs. A numerical method is developed to solve the model which also incorporates the operation of the load shedding protection. Some characteristic values on the frequency dynamic response are defined. These values are the undershoot, the overshoot and the residual frequencies, as well as the low frequency time intervals which are critical either for the system or for the turbines. In order to quantify the level of security, certain probabilistic indices concerning the characteristic values of frequency response (security) are presented, that are: the expected undershoot frequency due to a loss of generation event, the expected critical time for the turbines etc. The increase of security level by using the load shedding protection results inevitably in decreasing of the customer load reliability and quality. Therefore, some other probabilistic indices have to be defined. These incidents concern the load shedding (reliability) as they are, the expected duration of customer load interruptions, the expected annual not delivered energy due to the operation of the load shedding protection etc. Α new Monte-Carlo simulation method for setting the underfrequency load shedding protection of isolated power systems is presented. The method generates random times for the unit's failures and repairs and the operation of the system is simulated on the following three levels: first, the unit commitment and economic load-dispatching performed by System's Operator, second, the unit's primary regulation following each loss of generation event and third, the secondary regulation and the use of available spinning reserve. Using this method for a large number of year's operation, all the above probabilistic indices are evaluated. Therefore, by trial and error, it is possible to choose the load shedding strategy which provides acceptable probabilistic incidents. Then, two inverse problems which are more interesting for the praxis are formulated and analyzed. That are, given a vector of indices (either reliability or security), to determine the vector of appropriate load shedding strategy that satisfies the desirable indices. For this reason, a pattern generator is developed which produces vectors of random load-shedding strategies. Then, for each random strategy, the previous Monte-Carlo simulation method is used to calculate the respective vector of indices. The set that consists of a strategy vector and the respective vectors of indices is a pattern. These patterns are used to teach two multilevel artificial neural networks. Each network has as an input either the vector of reliability indices or the vector of security indices while the outputs are digital ones that correspond to predefined strategy classes. Finally, the contribution of short-time overloading of the generating units to the system security is studied. An improved speed-governor model is developed that permits the units short-time overloading according to the standards. A numerical method for optimal spinning reserve allocation in isolated power systems is developed. It is, also, demonstrated that only part of the emergency spinning reserve that is calculated by the equivalent unit model, actually exists. Moreover, a statistical analysis is committed showing that the correlation between spinning reserve and the frequency security criteria is about 70% and therefore, increasing the spinning reserve does not always implies improvement of the system security.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Thalassinakis, Emmanuil
  • Θαλασσινάκης, Εμμανουήλ

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/16962

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Thalassinakis, Emmanuil; Θαλασσινάκης, Εμμανουήλ. Πιθανοτική ανάλυση της αξιοπιστίας και ασφάλειας λειτουργίας των απομονωμένων συστημάτων ηλεκτρικής ενέργειας. National Technical University of Athens (NTUA), 2008. http://hdl.handle.net/10442/hedi/16962