Back to search

National Technical University of Athens (NTUA)

Συμβολή στον έλεγχο και στην προσομοίωση συστημάτων ισχύος χαμηλής τάσης με διεσπαρμένη παραγωγή

Abstract

dc:description

The drivers of dispersed generation urge its extension to the low voltage network, for which it is contemplated installation of numerous small capacity generators with diverse technical characteristics that are connected using voltage source inverter at their output. Sources and loads as a whole will constitute a single entity for the upstream network, also called microgrid, which shall be able to operate autonomously as a self-regulated island in the event of problems to the upstream network, a fact that entails higher consumer reliability and extension of the dispersed generation production. Islanded operation depends on paralleling the voltage source inverters of the distributed sources that are capable of regulated power output. Inverter paralleling using only local measurements is implemented with proportional control of frequency and voltage with active and reactive power output respectively. The installation of storage devices is necessary due to the fact that the created AC system will lack any form of inertia. This work focuses on the autonomous operation. The local control of the sources through their inverter is investigated so that stable operation is secured. Control methods are proposed so that typical system functions such as load or local generation fluctuations take place smoothly without power oscillations, which is translated to voltage and frequency regulation. The inverter at the output of the sources has implications, except from the operation, to the modeling itself that is needed for the dynamic analysis of the system. Therefore the transient stability methods, as applied to a system with synchronous machines, are adapted for application to an isolated system with voltage source inverters, accounting also for the asymmetries of low voltage network. So, the simulation of the dynamic behavior of the system can be carried out, testing various control strategies according to the characteristics of the power output change of each source. The behavior of the system depends on the magnitude and angle of the impedances that interconnect the voltage source inverters as well as on the control parameters, which are the droops of the frequency and voltage of the inverters with powers and the delay involved in this change. The factors that define the scope of the controlled system parameters are examined first. Controlling frequency with active power has the advantage that the active power production of each source is defined exclusively with the control parameters, irrespective to the position in the network. The influence of the resistance to reactance ratio is considered and specific means to improve the control performance is proposed. System stability is thoroughly analyzed considering two inverters in parallel and applying control methods of the classical control theory. The network dynamic is also included in the analysis on account of the fast response of the inverter. A specific compensation is proposed to improve the relative stability so that the defined response specifications are met for the anticipated system parameters. A large percentage of the load in the low voltage is non linear, thus if the control is confined to the fundamental frequency, voltage distortion may prove prohibitive for the islanded operation. The proposed method employs closed loop control of the terminal voltage and feed forward of the load current for each voltage source inverter, thereby achieving good voltage quality and harmonic sharing among the inverters in proportion to their capacity. The control implementation is in the time domain using instantaneous values thus with overall harmonic compensation. The application of the control method is tested with simulations.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Soultanis, Nikolaos
  • Σουλτάνης, Νικόλαος

Subjects

dc:subject × 22

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/17397

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Soultanis, Nikolaos; Σουλτάνης, Νικόλαος. Συμβολή στον έλεγχο και στην προσομοίωση συστημάτων ισχύος χαμηλής τάσης με διεσπαρμένη παραγωγή. National Technical University of Athens (NTUA), 2009. http://hdl.handle.net/10442/hedi/17397