University of Ioannina
Ανάπτυξη κώδικα Monte Carlo με τη μέθοδο των συμπυκνωμένων ιστοριών και εφαρμογή στην δοσιμετρία ηλεκτρονίων σε υποκυτταρικό επίπεδο
Abstract
dc:descriptionΤhe detailed-history MC4 code, which have been developed at the Medical Physics Laboratory of the University of Ioannina for the simulation of electrons with energies up to 10 keV in water, was modified and extended to higher energies (up to 1 MeV) using three different methodologies of the condensed history (CH) technique. Dose Point Kernel and Depth Dose distributions for monoenergetic electrons in water were calculated and the influence of the different CH methodologies and the phase effects of water on these distributions was studied. MC4 was benchmarked against nearly all available (general-purpose) CH codes. The effect on the above dose distributions of different models for the elastic scattering cross section and (soft-collision) energy-loss straggling was also investigated. Absorbed fractions and S-values for monoenergetic electrons uniformly distributed at different regions of unit-density spherical volumes with radius from 10 nm to 10 μm (sub-cellular scale) were calculated and compared with those obtained by the methodology of the MIRD (Medical Internal Radiation Dose) Committee. The latter calculations are based on analytic range-energy relationships and the Continuous Slowing Down Approximation (CSDA). Finally, the influence on the S-value of the three CH simulation methodologies was also investigated. The dose distribution results reveal that the inclusion of δ-ray transport causes the extension of dose profiles to larger distances with smaller peak values. The influence of the phase effects of water was found to be negligible in the examined energy range. The agreement between the results of MC4 and those from other codes is on the whole fairly good. With respect to the influence of different elastic scattering cross section models, we concluded that by an appropriate selection of the screening parameter in the screened Rutherford formulae and by using the relativistic Berger factor, a major improvement of the results may be achieved. The choice of different (soft-collision) energy-loss straggling distributions becomes important only at the tail of the dose profiles. In the calculated absorbed fraction and S-value distributions the MC values are higher than those of the MIRD method at energies where the penetration depth is comparable to the diameter of the sphere since the energy loss obtained by the analytic Cole-Howell formulae underestimates the corresponding from MC simulations. The situation is reversed at sufficiently high energies where the MIRD method overestimates both the absorbed fraction and the S-value since it neglects δ-rays. In general, the differences between the published S-values of the MIRD Committee and those from MC4 at the cellular level was found to be smaller than ~20 % for . Finally, the study of the S-value distributions obtained by the three CH methodologies demonstrated that the effect of (soft-collision) energy-loss straggling on these distributions is negligible.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Bousis, Christos
- Μπούσης, Χρήστος
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/17815