University of Ioannina
Ανάπτυξη εμπεδησιομετρικών βιοαισθητήρων σε επιφάνειες τιτανίου και χρυσού για την άμεση παρακολούθηση της σύζευξης βιομορίων και την ανίχνευση salmonella typhimurium σε πραγματικά δείγματα
Abstract
dc:descriptionCHAPTER 1: In the first chapter are described the advantages and limitations of impedimetricsensors based on Ti/TiΟₓΗᵧ architectures. Titanium oxide (titania) was potentiostatically formed onto titanium electrodes of 2 mm diameter, at 10 and 30 V in 1 Μ H₂SO₄. Their thickness was ellipsometrically determined 30 and 86 nm respectively and they are highly insulating with charge-transfer resistances in the megaohn range, as they were measured with electrochemical impedance spectroscopy under specific experimental conditions. Low voltage anodization (<10 V) results to amorphous TiO₂, where at higher applied voltages (>25 V), anatase is the predominant form. SEM images are indicative of quite smooth, compact coatings without any severe cracks. Titania films were further treated with sodium hydroxide to increase the population of hydroxyl groups onto the outer oxide layer. Various silanization procedures based on liquid and gas-phase anhydrous conditions were employed to produce amino-terminated surfaces. Using glutaraldehyde as a cross linker, avidin was immobilized by chemical bonding. All impedimetric measurements were performed using biotinylated dextran as the target analyte. The initial conductivity of titanium/titania electrodes, as it can be managed by means of the hydroxylation process (duration of chemical etching) as well as the silane layer are major factors affecting the performance of the resultant biosensors. Extended studies using electrochemical impedance spectroscopy provide important new insights into the mechanism of the signal transduction and the physical factors that control the nature of the measuring signal. CHAPTER 2: The development of an immunosensor for the direct probing of the interaction between a cysteine-modified synthetic peptide, which corresponds to the epitope cTnC-89-98 of troponin C, and its specific antibody is described. Following immobilization of the peptide onto gold electrodes through the formation of a self-assembled monolayer, the alteration of the interfacial properties of the electrodes upon peptide-antibody interaction was traced by faradaic electrochemical impedance spectroscopy (EIS) using a silicotungstic heteropolyacid, H₄SiO₄.12WO₃, as a redox probe. The electrochemical behaviour of the redox probe was evaluated with cyclic voltammetry and EIS. The effect of milk protein or 4-mercaptophenol, which were used as post-blocking agents, on the performance of the immunosensor, was investigated. Treatment with 4-mercaptophenol resulted in immunoeffective electrodes that successfully tested in anti-serum samples. An optimum dilution ratio of the samples, where the effect of the matrix on the measuring signal is negligible, was also determined. CHAPTER 3: In this chapter is described for first time the development of a faradaic impedimetric immunosensor for the detection of S. typhimurium in milk. Polyclonal anti-Salmonella was cross-linked, in the presence of glutaraldehyde, on gold electrodes modified with a single 11-amino-1-undecanethiol (MUAM) self-assembled monolayer (SAM) or a mixed SAM of MUAM and 6-mercapto-1-hexanol at a constant 1+3 proportion, respectively. The mixed SAM was also deposited in the presence of triethylamine, which was used to prevent the formation of interplane hydrogen bonds among amine-terminated thiols. The effect of the different surface modifications on both the sensitivity and the selectivity of the immunosensors was investigated. The alteration of the interfacial features of the electrodes due to different modification or recognition steps, was measured by faradaic Electrochemical Impedance Spectroscopy in the presence of a hexacyanoferrate(II)/(III) redox couple. A substantial amplification of the measuring signal was achieved by performing the immunoreaction directly in culture samples. This resulted in immunosensors with great analytical features, namely i) high sensitivity; the response of the immunosensors increases with respect to the detection time as a consequence of the simultaneous proliferation of the viable bacteria cells in the tested samples. ii) validity; the response of the immunosensors is practically insensitive to the presence of dead cells, iii) working simplicity; elimination of various centrifugation and washing steps, which are used for the isolation of bacteria cells from the culture. The proposed immunosensors were successfully used for the detection of S. typhimurium in experimentally inoculated milk samples. The effect of different post-blocking agents on the performance of the immunosensors in real samples was also examined.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Mantzila, Aikaterini
- Μαντζίλα, Αικατερίνη
Subjects
dc:subject × 22- Εμπεδησιομετρικοί βιοαισθητήρες
- Ηλεκτροχημική φασματοσκοπία εμπέδησης
- Ακινητοποίηση βιομορίων σε στερεά υλικά
- Ηλεκτροχημική ανάπτυξη οξειδίων
- Άμεση παρακολούθηση σύζευξης βιομορίων
- Άμεση ανίχνευση βακτηρίων σε γάλα
- Αναλυτής απόκρισης συχνότητας
- Χρήση ετεροπολυοξέος ως οξειδοαναγωγικού ανιχνευτή
- Impedimetric biosensor
- Electrochemical impedance spectroscopy
- Immobilization of biomolecules in solid materials
- Electrochemical development of oxides
- Direct monitoring of biomolecules interactions
- Direct detection of bacteria in milk
- Frequency response analyzer
- Use of heteropolyacid as a redox probe
- Χημεία
- Φυσικές Επιστήμες
- Αναλυτική χημεία
- Chemical Sciences
- Natural Sciences
- Analytical Chemistry
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/17831