Abstract
dc:descriptionThe present Ph.D. dissertation deals with the study of the ac induced voltage interference on the C.P. operation and impact on C.P. effectiveness concerning the anti-corrosion protection of buried-in-soil metallic pipelines. The measurements were performed under real conditions on the main pipeline of Greek Natural Gas grid, extending from Greek-Bulgarian border to Revithoussa islet in Attiki region, as well as on its several pipeline branches. The 50Hz ac voltage level on the pipeline is attained by the inductive interference from the close proximity and/or parallelism primarily with high voltage overhead power transmission lines and secondly with ac electrified railways. During the periodic inspection and monitoring of C.P. operation and maintenance on the transmission pipelines of the Natural Gas grid of Greece, ac interference caused by inductive effects of overhead high voltage powerlines as well as from dc and/or quasi-dc stray currents, especially telluric currents have been discovered. According to the initial design, at various sites along the pipeline route, overvoltage arresters had been connected across pipeline and earth electrodes. These overvoltage arresters, consisting of a set of antiparallel thyristors, are activated by ac voltage threshold level of 25V, a limit considered as a safety barrier for prevention from electric shock. The overvoltage arresters allowed pipeline to attain high ac induced voltage level (up to 25 V) for long time intervals, thus resulting in a high likelihood for corrosion caused by alternating currents (ac corrosion). In addition, this high ac interference level caused variations of dc potential and dc current. For the effective ac mitigation without degrading the pipeline cathodic protection function, special ac mitigation equipment, named Alternating Voltage Arresters Continuing Function (AVACF), were designed, constructed and installed at selected pipeline locations. AVACF were designed for conducting ac current while simultaneously effectively blocking dc current. After AVACF installation, C.P. system operation was significantly improved with the exception of instant-off C.P. pipe-to-soil potential readings falsification due to AVACF capacitor discharging currents. This phenomenon was thoroughly studied via an electric equivalent circuit simulating the system pipeline connected to earthing electrodes through capacitive equipment (e.g. AVACF). The effect of every parameter involved was investigated with regard to the falsification of instant-off potential readings. The most critical factors affecting the falsification of instant-off potential readings were disclosed and measures for minimising the instant-off potential readings error were suggested. Based on the results of the cathodic protection measurements used for inspection of C.P. system function, an improved modification of the test method for electrical isolation efficiency of installed insulating couplings was suggested. Various ac corrosion mechanisms and corrosion from telluric stray currents were discovered, investigated through recordings on Electrical Resistance (ER) probes connected to the pipeline at various locations along the pipeline route exhibiting different electrical and soil environment conditions.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Κιούπης, Νικόλαος
- Kioupis, Nikolaos
Subjects
dc:subject × 18- Επαγόμενες τάσεις
- Τελλουρικά ρεύματα
- Ρεύματα διαφυγής
- Σωληναγωγοί
- Διάβρωση από εναλλασσόμενο ρεύμα
- Καθοδική προστασία
- Εκτονωτής υπερτάσεων
- Induced ac voltage interference
- Telluric currents
- Stray currents
- Pipeline
- Ac corrosion
- Cathodic protection
- Overvoltage arrester
- Επιστήμες Μηχανικού και Τεχνολογία