The Euratom directive 97/43 recommends the use of patient dose surveys in diagnostic radiology and the establishment of diagnostic reference dose levels (DRLs). Dose measurements and the establishment of DRLs in diagnostic radiology is imperative in cases of patients that are relative more sensitive (pregnant women and children) or in cases that during the examination the time of fluoroscopy is long and the number of the acquired images is big. The present study aims to: 1. Perform measurements of the dose receiving during different x ray interventional examinations (angiographies). 2. The measurement of the dose receiving of the personnel that performs the examinations. 3. The export of diagnostic reference levels for the studied examinations. The measurements of the dose were done with thermoluminence dosimeters (TLDs). In details, measurements of the dose were performed during diagnostic angiography of the lower limbs of the renal arteries and of the carotids but also during coronary angiography and pacemaker implementation. During the dosimetry of the above examinations, various dosimetric quantities were acquired, and are capable to establish DRLs. In case of lower limbs angiography the proposed DRL was the entrance surface dose of 96.4 mGy in the pelvic region. During renal angiography was the entrance surface dose of 168,6 mGy at the level of the renal arteries and during angiography of the carotid arteries was the entrance surface dose of the 313 mGy at the level of the aortic arc. During coronary angiography the reference level was chosen to be 57,80 Gycm2 and during pacemaker implementation 19,4 Gycm2. The effective dose of the two above examinations was calculated to be equal to 10.1 mSv and 3 mSv respectively. Before the main part of this study, dose measurements was performed during micturating cystourethrography and during hysterosalpingography. Both examinations were performed using fluoroscopic images. The results reveal the decrease of the dose to the half, according to the results by other authors, during micturating cystourethrography and to the 1/3 during hysterosalpingography. The suggested diagnostic levels for the examination of micturating cystourethrography and hysterosalpingography, is the third percentile of the suggested entrance dose, which is equal to 1,7 mGy and the value of the third percentile of the suggested entrance dose being equal to 4,49 mGy or alternatively one x-ray, combined with fluoroscopy of 30 sec for the two examinations respectively.

Degree

thesis:*
Grantor dc:publisher
University of Thessaly (UTH)
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Τοπαλτζίκης, Θεόφιλος
  • Topaltzikis, Theofilos

Subjects

dc:subject × 10

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/18167

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Τοπαλτζίκης, Θεόφιλος; Topaltzikis, Theofilos. In vivo δοσιμετρία σε ασθενείς που υποβάλλονται σε ακτινολογικές εξετάσεις. Ανάλυση δόσης και καθορισμός διαγνωστικών επιπέδων αναφοράς. University of Thessaly (UTH), 2009. http://hdl.handle.net/10442/hedi/18167