University of Thessaly (UTH)
Ο ρόλος του οξειδωτικού stress στη διάγνωση των υπεζωκοτικών συλλογών
Abstract
dc:descriptionIntroduction: Oxidative stress has been associated with various respiratory disorders. Purpose: We tested the hypothesis that exudates would present higher levels of oxidative stress compared to transudates, expressing the increased local oxidative burst in the former. Material and Method: We studied 90 consecutive patients with a final diagnosis of their pleural effusion were admitted in the Respiratory Department of the University Hospital of Larissa(62 exudates and 28 transudates). The exudative pleural effusions were classified as malignant(n=40), tuberculus(n=8), due to other aetiologies(n=14). Subjects were submitted to diagnostic thoracentesis and standard biochemical parameters (total protein, albumin, lactate dehydrogenase and glucose) were measured in pleural fluid and serum. Oxidative stress levels were assessed with a commercially available method (d-ROMs test; Diacron, Grosseto, Italy), that uses conventional units (UCarr). In 14 patients with different diseases a second thoracentesis was performed on the following day for the assessment of repeatability of measurements with this method. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy for the characterization of exudates in different cut-off levels of oxidative stress were additionally calculated. Results: Oxidative stress levels were higher in exudates compared to transudates (274±72 UCarr vs. 126±34 UCarr; p<0.0001). Similar differences were noticed for each of the subgroups of the exudative pleural effusions compared to transudates (lung cancer 279±68 UCarr, other malignancies 266±67, TBC pleuritis 272±52, and other causes 268±93 UCarr, vs. 126±34 UCarr; p<0.0001 for each pair) (figure 1). No significant differences were found between the levels of oxidative stress in the subgroups of exudative pleural effusions (p=0.33). The method provided high sensitivity (96.8%), specificity (96.3%) and accuracy (95.6%) for the characterization of an effusion as an exudate, when a cut-off level of oxidative stress of 186 UCarr was used. The measurements of oxidative stress in the pleural fluid in two different thoracenteses performed on two consecutive days presented excellent repeatability. Conclusions: The levels of oxidative stress are higher in exudative pleural effusions compared to transudates, probably due to reactive oxygen species produced in the former. Oxidative stress levels were assessed with a rapid commercially available method that was highly repeatable in the cases studied and may serve as a marker for the differentiation between exudates and transudates in clinical practice.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Papageorgiou, Evangelia
- Παπαγεωργίου, Ευαγγελία
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/18190