National Technical University of Athens (NTUA)
Ανάλυση μηχανικής συμπεριφοράς οστών - εμφυτευμάτων με χρήση πεπερασμένων στοιχείων
Abstract
dc:descriptionTotal hip arthroplasty (THA) is nowadays a common treatment for a large number of pathological cases regarding the hip joint and is considered as the most successful orthopedic operation. With the mean age of patients constantly decreasing and a more intense way of life, the need for versatile implant designs has arisen. Currently modular hip implant systems are used extensively in order to compensate for difficult occasions. In addition to this, femoral heads of bigger diameter (BFH) have been introduced to deal with several issues, although the overall influence of modularity on the mechanical behavior on the bone-implant assembly is not widely documented. Towards this direction, the current study aims to investigate the biomechanical behavior of a commercial THA implant, using the finite element method. Computed tomographies of a cadaveric femur were used as raw data and processed along with a Profemur-E system with variable heads that was digitized. This led to a complete assembly consisting of the whole femur volume, the stem, the necks and the femoral heads in the CAD software Solidworks® and ultimately in a highly accurate -for the finite element analysis and from a clinical point of view, model. For typical loading scenarios - the stance phase of the gait cycle - the finite element analysis was performed in ANSYS Workbench®. According to the medical team involved, the combinations available due to modularity-both from necks and femoral heads- is still under extensive investigation. The neck version (angle and positioning-ante/retro) and the head diameter were set as the main parameters and the stresses / strains for several areas of clinical interest such as the calcar, the greater trochanter area and the stem tip region, considered responsible for thigh pain, were analyzed. This was considered as one of the main elements of originality in the current study, since there are only few bioengineering studies examining the modularity from such a wide aspect. In conclusion, the results of the FE analysis were compared to several clinical observations - both from radiographic data, statistical analysis and patient tests, from an early post-op patient series. It was finally observed that, the mathematical finite element models had a strong degree of correlation to the clinical data, thus allowing them to be used as reference data by the medical team and as a tool for a better understanding of the behavior of modular implants and their design variations.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Θεοδώρου, Ευάγγελος
- Theodorou, Evangelos
Subjects
dc:subject × 15- Ολική αρθροπλαστική ισχίου
- Ανάλυση πεπερασμένων στοιχείων
- Διαιρούμενα εμφυτεύματα
- Διαιρούμενοι αυχένες
- Σύστημα ολικής αρθροπλαστικής ισχίου Profemur-E
- Προεγχειριτικός σχεδιασμός
- Total hip Arthroplasty
- Finite element analysis
- Modular necks
- THA system: Profemur-E
- Preoperative planning
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Μηχανολόγου Μηχανικού
- Engineering and Technology
- Mechanical Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/18209