Back to search

National Technical University of Athens (NTUA)

Ανάλυση μηχανικής συμπεριφοράς οστών - εμφυτευμάτων με χρήση πεπερασμένων στοιχείων

Abstract

dc:description

Total hip arthroplasty (THA) is nowadays a common treatment for a large number of pathological cases regarding the hip joint and is considered as the most successful orthopedic operation. With the mean age of patients constantly decreasing and a more intense way of life, the need for versatile implant designs has arisen. Currently modular hip implant systems are used extensively in order to compensate for difficult occasions. In addition to this, femoral heads of bigger diameter (BFH) have been introduced to deal with several issues, although the overall influence of modularity on the mechanical behavior on the bone-implant assembly is not widely documented. Towards this direction, the current study aims to investigate the biomechanical behavior of a commercial THA implant, using the finite element method. Computed tomographies of a cadaveric femur were used as raw data and processed along with a Profemur-E system with variable heads that was digitized. This led to a complete assembly consisting of the whole femur volume, the stem, the necks and the femoral heads in the CAD software Solidworks® and ultimately in a highly accurate -for the finite element analysis and from a clinical point of view, model. For typical loading scenarios - the stance phase of the gait cycle - the finite element analysis was performed in ANSYS Workbench®. According to the medical team involved, the combinations available due to modularity-both from necks and femoral heads- is still under extensive investigation. The neck version (angle and positioning-ante/retro) and the head diameter were set as the main parameters and the stresses / strains for several areas of clinical interest such as the calcar, the greater trochanter area and the stem tip region, considered responsible for thigh pain, were analyzed. This was considered as one of the main elements of originality in the current study, since there are only few bioengineering studies examining the modularity from such a wide aspect. In conclusion, the results of the FE analysis were compared to several clinical observations - both from radiographic data, statistical analysis and patient tests, from an early post-op patient series. It was finally observed that, the mathematical finite element models had a strong degree of correlation to the clinical data, thus allowing them to be used as reference data by the medical team and as a tool for a better understanding of the behavior of modular implants and their design variations.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Θεοδώρου, Ευάγγελος
  • Theodorou, Evangelos

Subjects

dc:subject × 15

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/18209

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Θεοδώρου, Ευάγγελος; Theodorou, Evangelos. Ανάλυση μηχανικής συμπεριφοράς οστών - εμφυτευμάτων με χρήση πεπερασμένων στοιχείων. National Technical University of Athens (NTUA), 2009. http://hdl.handle.net/10442/hedi/18209