Abstract

dc:description

The radiation therapy treatment planning process is complex and involves multiple steps and a number of technologies. Requirements for the accuracy of a treatment planning system (TPS) must be seen in the light of the total uncertainty in the 3-D dose delivery to a patient, taking into account all steps in the planning and delivery process. The overall accuracy in the radiation dose delivered to the patient is ±5%¶ of the prescribed dose. ¶To satisfy this requirement, a 2-3% accuracy is required in the dose calculation. ¶Due to the semi-empirical character of used algorithms, which are based partly on measurements and mainly on analytical calculations, it should be prescribed the methods and techniques to ensure the precision of their results.¶ The quality of the treatment plan is not based only on the dosimetric calculations, but also on other physical parameters such as the beam geometry and the anatomical structure of patient. ¶The algorithms that are used for the management and the 3D reconstruction of images, as well as the tools of plan evaluation are some of the parameters of TPS that require confirmation. ¶The TPS acceptance tests confirm the specifications that have been set by the company and are performed by the responsible physicist in collaboration with the vendor.¶Before Bgfh The present work presents all tests (dosimetric and not) that are required for proper operation of a TPS. The acceptance limits of deviations in dose calculations for various geometries and for various regions of dose gradient are proposed, according to the bibliography. In addition, the confidence levels have been proposed for some general cases of dosimetric controls. In the present thesis, the dosimetric tests were performed to PLATO and HELAX. The study took place in the department of radiotherapy of Areteio hospital and the oncology center of Hygeia hospital for 6MV beam quality. Since the number of data points is adequate to obtain statistically relevant conclusions, it can be applied the following method. The comparative evaluation of two TPS is performed with the before mentioned methodologies and moreover is proposed the statistical method of quality control “six sigma” according to which are checked the proposed limits of deviation and moreover are proposed new ones. The new limits depend on the values of the process capability indices as are proposed by the methodology of “six sigma”. Each TPS is evaluated by the recommendation of stricter or wider limits of deviation.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Σεφερλής, Σταύρος
  • Seferlis, Stavros

Subjects

dc:subject × 8

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/18344

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Σεφερλής, Σταύρος; Seferlis, Stavros. Έλεγχοι αποδοχής και ποιότητας συστημάτων σχεδιασμού ακτινοθεραπείας. National and Kapodistrian University of Athens, 2007. http://hdl.handle.net/10442/hedi/18344