Back to search

National and Kapodistrian University of Athens

Ηλεκτρονική συσκευή στοχεύσεως για την ακριβή χωροταξική τοποθέτηση του μοσχεύματος στην πλαστική του προσθίου χιαστού συνδέσμου

Abstract

dc:description

Aim: The aim of the current project is the construction of an electronic device that would help the surgeon to drill a bone with accuracy, regardless of his abilities in this area and reducing the time taken for this procedure as well. Materials-Method: Drilling a bone which is held steady in space is bounded by the selection of an entry point A and an exit point B. This is feasible with the aid of a mechanical tool equipped with accelerometer and magnetic sensors interfaced to a micro-controller. The micro-controller represents the processing power available as well as the interconnecting possibilities, so the right choice is of vital importance. It will be necessary to interconnect to the accelerometer sensors, the magnetic sensor and the Liquid Crystal Display (LCD). Also, serial interconnection to a Personal Computer (PC) is important, but the execution of filter algorithms is the most power consuming task. The size of the Printed Circuit Board (PCB) and of the housing have been minimized as they will be mounted on the mechanical tool and the drill. The housing of the main board was not necessary at this experimental stage. The tool software deals with sensor data and transfers them to the drill software. The drill software deals with sensor data, interfacing of the LCD and printing to it. It also receives data from the toll software. The data collection software converts hexadecimal data to decimal, for further processing with the aid of MATLAB software. The output of the sensors contain unwanted signals (noise) that needs to be removed, so that the reading can be useful. This is achieved with digital filters. Results: The values of X1, X2 and Y1, Y2 show the deviation from the horizontal and vertical axis respectively, while the values Radius-1 and Radius-2 show the deviation as a radius from the centre of the desired output point until the centre of the real drilling. The drilling results in each case show a mean value less that 1mm for X1 and X2, while for Y! and Y2 the mean is 1.64mm approximately. The mean for R1 and R2 are very close to 2mm. Conclusions: The use of the proposed device produced significant improvement in drilling accuracy compared to the available Computer Aided Surgery (CAS) electronic tools. Visual representation is lacking though in comparison, a fact that slightly increases the drilling time and also generates a need for some kind of familiarization.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Papachristou, Konstantinos
  • Παπαχρήστου, Κωνσταντίνος

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/18347

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation