University of Thessaly (UTH)
Μεσοπρόθεσμα αποτελέσματα ολικής αρθροπλαστικής του ισχίου με μεταλλικές επιφάνειες τριβής: (Μέταλλο με Μέταλλο)
Abstract
dc:descriptionThe aim of this study is to report clinical and radiological mid-term results (6-15 years) of metal on metal Zweymuller total hip arthroplasty. 99 THA on 84 patients were followed up for a mean period of 9.5 (range, 6-15) years. There were 29 (34.5%) male and 55 (65.5%) female patients with a mean age of 62.85 years (range, 50-70 years) at the time of surgery. For all patients the diagnosis was idiopathic osteoarthritis. Patients were assessed clinically and radiologically. Factors such as implant migration, osteolysis appearance, radiolucent and radiodense lines, osteopenia, cortical thickening were recorded. Statistical analysis of diverse factor effect on implant survival and aseptic loosening was performed. Any complication was noted and discussed. One acetabular component and one stem were revised due to aseptic loosening. One femoral stem was also revised due to a periprosthetic fracture. HHS score was improved from a preoperative mean of 62.56 points (SD 8.87) to a final postoperative follow-up mean of 93.48 (SD 7.7). Another 2 patients underwent revision surgery for THA components exchange in order to improve stability following dislocations. Cumulative success rate for both implants at 13 years, with aseptic loosening as the end point, was 97.05%, while for both implants at 13 years, with revision for any reason as the end point, it was 91.17%. The cumulative probability of having no cup osteolysis at 13 years was 80.04%. The cumulative probability of having no femoral subsidence greater than 5mm in 13 years was 73.43% , of having no femoral osteolysis was 67.25% and of having no cortical thickening was 83.34%. The use of inlay with additional inclination angle does not reduce dislocation probability. The results confirm the literature, and all stems appear to be osseointegrated. Despite the manufacturers’ suggestion, that the rounded tip of the stem reduces local load concentration, we concluded the opposite. Cortical thickening was common in this study, probably due to an increased distal load transfer. Satisfactory results were shown with the use of this prosthesis. Although our study has a limited number of patients and lacks a control group for comparisons, we conclude that this prosthesis with a metal on metal combination as bearing offers successful results, especially in young, active patients. The most important findings of our study are the low rate of stem and cup revision for aseptic loosening, the low rate of radiographic signs of loosening, and the low rate of distal femoral osteolysis. Inlay exchange with another with an additional 10o inclination, was the most common reason for the revision of the acetabular component in our series. The long-term results and investigation of possible complications due to metal particle release demand long-term multicentre cooperation and a large number of patients.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Palaiochorlidis, Elias
- Παλαιοχωρλίδης, Ηλίας
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/18637