Aristotle University Of Thessaloniki (AUTH)
Μελέτη των καταστάσεων πλημμύρισης σε αναδευόμενα συστήματα αερίου-υγρού
Abstract
dc:descriptionMechanically agitated gas-liquid contactors are widely used in industry, offering optimal dispersion conditions and great efficiency of gas utilization in the reactor. Different definitions of flooding have been proposed by several investigators. The definition that has been used extensively by most investigators was the one that defined flooding as the ceasing of the radial motion of the bubbles in the impeller stream. This definition seems to be the most popular one because of the fact, that the situation described above is easy to be observed and realized experimentally. Therefore, the flooding-loading transition is widely used, for the estimation of the working conditions, due mainly to its experimental convenience and accuracy. However, the dispersion is ineffective at this stage, since the gas bubbles are sufficiently dispersed only in the zone above the impeller. On the contrary, the complete dispersion conditions give efficient dispersion characteristics, as the whole of the tank is efficiently used. Consequently, the complete dispersion condition is the one that determines the optimal working conditions. Although, several investigators have worked on flooding-loading transition and loading-complete dispersion transition stages, limited data are available in the literature on the interrelation of these two transitions. Therefore, in this Ph.D. Thesis, the flooding-loading and the loading-complete dispersion transitions are both extensively studied, using different measuring techniques. In the literature, visual observation is very often used for the determination of these two transitions. However, this technique needs both the agitated vessel and the liquid to be transparent, and therefore cannot be used if they are not. In this study, a new method for the determination of the flooding-loading transition is proposed, using light transmission technique. In addition, experimental results concerning both flooding-loading and loading-complete dispersion transitions are compared for gas-liquid contactors agitated by one or two Rushton turbines of different diameters, for coalescing and non-coalescing systems. Furthermore, an interrelation between these two transition stages is proposed, in the form of a correlation between FrF and FrCD (i.e. the Froude number at the flooding-loading transition and the loading-complete dispersion transition, respectively). The resulting correlation is of theoretical and practical importance, since no data are available on the literature on this subject matter.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Babalona, E.
- Μπαμπαλώνα, Ευανθία
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/19265