Aristotle University Of Thessaloniki (AUTH)
Παράγοντες που επηρεάζουν τη διάρκεια και την καλή λειτουργικότητα της φωνητικής πρόθεσης σε ασθενείς με λαρυγγεκτομή
Abstract
dc:descriptionObjective: Total laryngectomy usually affects in a catalytic way the production of voice, the respiratory function as well as the personal and social life of the laryngectomises patient. Since the introduction of the tracheoesophageal voice restoration by Singer and Blom in 1979, the prospective of a successful method of voice rehabilitation following laryngectomy was raised. In addition to esophageal speech and artificial larynx, a great number of patients achieved an intelligible, functional speech, which is much closer to “normal speech”, requires minimum effort and provides a worldwide accepted method of voice restoration after laryngectomy. Aim: Purpose of the current study is to identify and analyze factors which contribute in adequate function and duration of the voice prosthesis. Factors introduced and analyzed were: the influence of radiotherapy, neck dissection, size of the voice prosthesis, saliva’s electrolyte composition and pH, bacterial and fungal colonization of voice prosthesis, pulmonary function, efficacy of voice production among with phonation characteristics and probable correlation in voice prosthesis’ function and duration. Materials and methods: A retrospective review was performed in 70 laryngectomised patients between 1st of January 1998 until 1st of January 2005. All patients included in the study had a total laryngectomy performed and voice prosthesis was used to restore speech after surgery. Voice prosthesis used was the PROVOX (ATOS Medical AB, Hosby, Sweden), type Ι and ΙΙ. The PROVOX voice prosthesis was inserted through the tracheosophageal fistula and cannot be removed or replaced from the patient. Replacement of the Provox voice prosthesis is carried out with a disposable insertion tool (a loading tube and an inserter) for the insertion of the voice prosthesis directly through the stoma into the fistula. The technique is well tolerated from the patient but requires some technical skill and ability from the physician, so it can be adequate placed through the tracheosophageal fistula. Results: Fifty-one male patients met the introduction criteria. The number of voice prosthesis studied was 160. Patient’s age was between 51 and 76 years (mean age 66 years). All patients retained adequate voice prosthesis function for a significant period of time. The duration of voice prosthesis studied was between 10 to 46 weeks. Most of voice prosthesis studied (51 prosthesis), remained functional between 24 and 28 weeks. The size of voice prosthesis did not influence the total time in which voice prosthesis did remain functional. In our work increased sized of voice prosthesis correlated with minimized bacterial and fungal colonization. Radiotherapy, through the decreased salivary flow, did influence the duration of voice prosthesis. On the other hand, neck dissection was not a factor of diminished functionality. Radiotherapy was not correlated with the number of bacteria isolated from the silicone material. Liturgical voice prosthesis correlated with an increased number of bacteria, but there was no evidence that this fact related, in any way, with patient’s morbidity. In cases with a diminished salivary flow, an increased number of bacteria and fungal colonization was noted, and a decreased functionality and duration of voice prosthesis was also present. Increased saliva’s pH levels had an impact in prosthesis duration. Average increased level of saliva’s pH was correlated with adequate voice prosthesis functionality and duration. The most frequent bacteria isolated from voice prosthesis were Staphylococcus aureus in 48.5% of all cases. Even when there was only one type of bacteria present, Staphylococcus aureus was the dominant type with 15.8%. In cases of fungal colonization, the most frequent type isolated was Candida albicans, with 66.9%. Pulmonary function was efficient in all cases for voice production, even after radiotherapy or neck dissection. The size of voice prosthesis had no effect in pulmonary function and voice production. There was not a statistical significance between pulmonary parameters measured and radiotherapy or the size of voice prosthesis. In our work fluency, maximum phonation time, articulation and speech rate were not correlated with alterations caused by radiotherapy or the size of voice prosthesis. Additionally, all patients were able to communicate through the telephone with the environment. Quality voice was able to be produced by all study patients and this has an affirmative impact in patient’s social and professional aspects of their life. Based on patient’s respond to the questionnaire filed in every voice prosthesis replacement, there was a clear consequent that voice prosthesis functionality was related with the number of times in which patient cleaned the prosthesis through the day. Consistent use of the cleaning brush device was an observation noted in all patients with sufficient voice prosthesis functionality. Local and general personal hygiene was the most important factor to maintain quality of speech and use of voice prosthesis with no major concerns for a significant period of time. Cleaning hands regularly minimizes the number of bacteria which transfer through fingers to voice prosthesis in cases when a stoma button is not used. Conclusions: Adequate hydration and salivary flow especially in a previously radiated field, among with thorough personal hygiene and consistent cleaning of the prosthesis were the most important factors contributed in voice prosthesis functionality and duration noted in our work.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Κυροδήμος, Ευθύμιος
- Kyrodimos, Efthymios
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/19473