Aristotle University Of Thessaloniki (AUTH)
Αιμοδυναμικές μεταβολές μετά από βραχιόνιο - βασιλική αρτηριοφλεβική επικοινωνία
Abstract
dc:descriptionAutogenous arteriovenous access at the upper extremities for chronic hemodialysis reasons are a primary arteriovenous access option, as they are associated with decreased rates of infection and failure and increased average patency compared to prosthetic-graft fistulas. However, improved treatment has increased the overall life expectancy of patients undergoing chronic hemodialysis for end-stage renal failure. Therefore, the commonly applied sites for autogenous arteriovenous fistulas (AVF) are often thrombosed during the course of time and a prosthetic-graft fistula is required. Basilic vein transpositioning is an alternative autogenous angioaccess option before performing a prosthetic-graft AVF. The aim of this study was to analytically describe the technical details for performing the specific AVF and to evaluate the correlation between the standards applied in this study (length of the anastomosis: 7mm, length of the basilica vein: 12 cm, diameter of the AVF > 12mm) the maturation rate of the AVF and the blood flow distal to the anastomosis. Intra and Post operative arterial steal syndrome in the contra-lateral upper extremity was also evaluated in correlation with the native and systemic haemodynamic effects of a brachial artery-basilic vein AVF. A total of ten basilic vein transpositioning procedures were performed in patients (mean age: 65.10 ± 9.10 years) undergoing haemodialysis for chronic renal failure in Papageorgiou General Hospital (Thessaloniki, Greece). Basilic vein transpositioning was chosen as an alternative because all other sites for autogenous arteriovenous angioaccess in the upper extremities had been thrombosed or due to improper vessel anatomy. The following steps were involved in the operative technique: 1. the basilic vein was exposed and mobilised under local anaesthesia (lidocaine); 2. an end-to-side anastomosis was performed between the basilic vein and the brachial artery at the level of the inner elbow joint in order to create an arteriovenous fistula; 3. the basilic vein was transposed subcutaneously so that the vessel could be easily catheterised for hemodialysis reasons in the future. The blood flow at the level of the basilic vein after performing the arteriovenous fistula and the blood flow at the level of the brachial artery, both proximally and distally to the anastomosis, were recorded intra-operatively using a high-fidelity “transit-time” ultrasound flow-meter (MediStim, Norway). The digital-brachial index (DBI: the arterial pressure at the level of the ipsilateral index finger divided by the arterial pressure of the contralateral brachial artery) was also recorded intra-operatively, using a digital arterial pressure measuring device (DinaMap). Finally, we recorded the variations of the patients’ cardiac output intra-operatively by catheterizing the contralateral radial artery inserting a cardiac-output probe into the vessel. The probe was connected to an appropriate monitor (Vigileo, Edwards Lifesciences), which continuously provided information regarding the arterial pressure wave, the subjects’ cardiac output and the pressure of the pulse wave. The specific device has been approved for all clinical applications by the FDA. Finally, we clinically evaluated the advent of arterial steal syndrome both intra and post operatively. In all cases the basilic vein was free of fibrosis and once the vessel had been exposed and mobilized the available autogenous graft was at least 3mm in diameter and 12cm in length. The arteriovenous fistula was patent in all subjects and was used for hemodialysis within 24 – 30 post-operatively, once it had matured. The mean flow of the arteriovenous fistula, as recorded intra-operatively, was 953.60 ± 313.28 ml/min. This denotes that the specific approach is potent for hemodialysis, as a blood flow above 350 ml/min is considered efficient for hemodialysis purposes. No patients developed any symptoms that would be suggestive of arterial steal syndrome ipsilaterally to the AVF, both intra-operatively and during the post-operative period. The DBI, as recorded intraoperatively, was above 0.6 in all cases, which is an objective indicator of the absence of arterial steal syndrome. The mean arterial-pressure at the contra-lateral brachial artery, after performing the AVF was significantly lower (98.17±11.39 mmHg vs. 89.40±11.38 mmHg). The cardiac output (CO) after performing the AVF increased in all cases. The mean CO was initially 5.37±1.50 L/min (range: 3.9 – 8.4), which increased to 6.55±1.98 L/min (range: 4.3 – 10). The mean increase of the CO was 1.18 L/min (21,97%). The DBI is not significantly related to the change observed in most major haemodynamic parameters after performing the AVF (CO, blood flow at the level of the AVF and the distal brachial artery). The DBI increased in all patients 30 days after the operation and once the AVF had matured. During the follow-up (range 4 – 15 months) a total of 2 AVFs had failed. In one case the basilic vein was partially occluded due to fibrous-tissue formation. The second patient was diagnosed with intimal hyperplasia at the site of the anastomosis. Conclusively, basilic vein transposition is a good autologous angioaccess alternative for hemodialysis reasons when the common access sites at the upper extremities are no longer patent. The main advantages of the specific technique include the high blood-flow at the level of the AVF, the need to only perform a single anastomosis and the low rates of infection and arterial steal syndrome.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2007
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Saratzis, Nikolaos
- Σαρατζής, Νικόλαος
Subjects
dc:subject × 10Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/19526