National Technical University of Athens (NTUA)
Εφαρμογές μη γραμμικής δυναμικής στην ανάλυση ευστάθειας τάσης
Abstract
dc:descriptionThis thesis utilizes the rich theoretical background of nonlinear dynamic systems in order to analyze phenomena, which arise during the operation of power systems and affect voltage stability. These phenomena, such as the disappearance of equilibrium points, or the onset of oscillations related to the presence of periodic orbits (limit cycles), are interpreted using bifurcation theory. The dynamic behavior of some basic load components of a power system, such as Load Tap Changer (LTC) and induction motors, when bifurcation conditions are met, is analyzed with the help of phase portraits. Moreover, more complicated phenomena, such as higher codimension bifurcations, are analyzed and verified. The determination of stability conditions and the boundaries of the region of attraction in the state space of a power system with LTC dynamics are examined. The dynamic behavior of LTCs is studied using the approximate continuous model, as well as the discrete model, which describes more accurately the actual LTC operation. The thesis also deals with the study of hybrid systems, which include the simultaneous operation of both continuous and discrete dynamic components and therefore they correspond to a more realistic power system operation. Regarding the discrete model of LTCs, the region of attraction of the stable equilibrium set is fully recognized with the use of LaSalle’s Invariance Principle. The theoretical foundation of the region of attraction results in the determination of stability conditions in terms of easily measured quantities, such as voltages and transformer tap ratios. The properties and conclusions that have arisen from the study of the region of attraction are used for the planning of load shedding schemes to save the system in an unstable situation. The necessity of an adequate and timely load shedding action is verified, while the possibility of undesirable and possibly not easily identified conditions in systems with deadband, such as trajectory trapping in an unstable equilibrium set, is examined. In this framework, an algorithm for calculation of the critical load shedding time, when a specific load shedding action has been selected, is proposed. The thesis also studies the issue of the timely identification of an upcoming possible voltage instability. Towards this goal, evaluating the properties of the state matrix of the system, a method based on the comparison of successive values of LTC voltages is proposed. This method is decentralized, since only local measurement is needed for the issue of an alarm signal. Based on this method an integrated protection scheme may be designed incorporating the application of corrective measures. The effect on the maximum power transfer of power factor and voltage control with the use of reactive compensation devices, is also examined in this thesis. Additionally, the use of capacitor banks for the primary side voltage control besides the power factor control, of a typical substation of the Greek power system is also studied through simulation.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Sakellaridis, Nikolaos
- Σακελλαρίδης, Νικόλαος
Subjects
dc:subject × 18- Μη γραμμικά συστήματα
- Διακλαδώσεις
- Ευστάθεια Lyapunov/LaSalle
- Διακριτή δυναμική
- Περιοχή έλξης
- Ευστάθεια τάσης
- Κρίσιμος χρόνος αποκοπής φορτίου
- Nonlinear systems
- Bifurcations
- Lyapunov/LaSalle stability
- Discrete dynamics
- Region of attraction
- Voltage stability
- Critical load shedding time
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/19640