National and Kapodistrian University of Athens
Συγκριτική μελέτη της αποτελεσματικότητας και της ασφάλειας του συνδυασμού των οφθαλμικών σταγόνων AGN 192024 (bimatoprost ) 0.03% και τιμολόλης 0.5% με τον ανάλογο συνδυασμό λατανοπρόστης 0.005% και τιμολόλης 0.5% στην αντιμετώπιση του χρόνιου απλού γλαυκώματος
Abstract
dc:descriptionIn the present study, the effect of the combination of ocular drops AGN 192024 0.03% + timolol 0.5% on the elevated intraocular pressure (IOP) and the comparison of this combination with the similar one of latanoprost 0.005% + timolol 0.5% are studied. The 48-hour curve of IOP in patients with open angle glaucoma, after the instillation of one single drop of AGN 192024, is registered. The effects of latanoprost 0.005%, timolol 0.5% and its combination on the respiratory system of patients with mild or moderate bronchial asthma, as well as, the efficacy of latanoprost 0.005% on the IOP when it is administered with glucocorticoids, are also studied. RESULTS and CONCLUSIONS. 1. Timolol eye drops caused statistically significant reduction of the values of FVC (vital capacity), FEV1 (expiratory outflow), FEV1% (an index expected to show changes in the large airways), FEF 50, FEF 75 and FEF 25-75 (indices expected to show changes in the small airways). Latanoprost drops did not seem to affect the above values. The combination of latanoprost + timolol did not cause further reduction of these values in comparison with the reduction caused by timolol alone. 2. The administration of glucorticoids in patients, already treated with latanoprost, did not affect the efficacy of latanoprost. 3. a. Combined administration of latanoprost 0.005% and timolol 0.5% (9 months): The greatest difference between the initial and the final mean value of the IOP was 9.75 mmHg (24.87- 15.12), meaning that the percentage of reduction was 39.2%. b. Combined administration of AGN 192024 0.03% and timolol 0.5% (9 months): The greatest difference between the initial and the final mean value of the IOP was 11.7 mmHg (29.6- 17.9), meaning that the percentage of reduction was 39.5%. c. There was no significant difference between the two combinations. The reduction of the IOP mean value was greater using AGN 192024 instead of latanoprost (2 mmHg), but the real difference in percentage was worthless (39.5% - 39,2%). The most common adverse effect in both groups was the conjuctival hyperemia (38% - 28%). 4. Instillation of one single drop of AGN 192024 0.03%: The reduction of the IOP began 4 hours after the instillation and reached the maximum values between the 8th and 14th hour. The greatest reduction was registered 12 hours after the administration (6.6 mmHg - 25.6%). The IOP remained in therapeutic levels until 36 hours after the instillation.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Bournas, Panagiotis
- Μπουρνάς, Παναγιώτης
Subjects
dc:subject × 14- AGN 192024 μπιματοπρόστη
- Ενδοφθάλμια πίεση
- Συνδυασμός λατανοπρόστης - τιμολόλης
- Συνδυασμός AGN 192024 - τιμολόλης
- 48ωρη καμπύλη
- AGN 192024 bimatoprost
- Intraocular pressure
- Combination latanoprost - timolol
- Combination AGN 192024 - timolol
- 48 hours curve
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/19660