National and Kapodistrian University of Athens
Η αγγειογραφική ανταπόκριση της ετερόπλευρης στεφανιαίας αρτηρίας κατά την αγγειοπλαστική της πρόσθιας κατιούσας αρτηρίας
Abstract
dc:descriptionThe mechanism of enhancement of the collateral circulation, during balloon angioplasty (PTCA), is still unclear. In order to investigate this phenomenon, we studied the angiographic response of the “normal” right and left circumflex coronary arteries during PTCA of the left anterior descending artery, in patients with stable angina. Furthermore we correlated the recruitability of coronary collaterals to the plasma cyclic guanosine monophosphate (c-GMP) levels. Finally, we investigated if the response of the contralateral artery is different in hypertensive than normotensive patients and whether this response is related to plasma levels of endothelin-1 (ET-1). Thirty patients with stable angina were involved in the study. Coronary angiograms were obtained at baseline, during maximal balloon inflation and at the end of the procedure. The luminal diameter was estimated, by using a quantitative coronary arteriography analysis system, while only proximal and distal segments of the right and circumflex arteries were studied. Grading of collateral filling of the dilated artery was classified, based on the presence and extend of the epicardial filling. Blood samples from a peripheral vein were taken for measurements of c-GMP and ET-1 plasma levels, at baseline, at the end of the 1st balloon inflation, at the end of the procedure, and 4 hours later. The diameter of the proximal segments of the right and circumflex arteries did not change significantly (p < 0.05), during balloon inflation, contrarily to the diameter of the distal segments that increased significantly. (p < 0.001). Both arteries returned to near baseline values after angioplasty. In patients with increased collaterals during balloon inflation, the left circumflex proximal segment increased more significantly than in patients with unchanged collaterals. Cyclic guanosine monophosphate levels were measured in 23 patients. In 8 patients collateral filling increased during balloon inflation (group A), while in 13 patients remained unchanged (group B). In group A, c-GMP levels increased from 8.57 ± 3.0 pmol/ml at baseline, to 11.53 ± 6.6 during balloon inflation, to 15.18 ± 7.7 at the end of the procedure, and decreased to 4.98 ± 0.85 four hours later. In group B, the respective values were 6.2 ± 2.6, 7.9 ± 4.4, 8.1 ± 4.7, and 4.2 ± 1.8. pmol/ml, (F = 10.68, p = 0.005). Endothelin-1 was measured in 15 normotensive and 8 hypertensive patients. In all the patients, taken as one group, ET-1 was increased significantly, at the end of the procedure. In normotensive patients, the ET-1 levels increased from 7.14 ± 2.71 to 10.04 ± 4.08 (F = 4.95, p = 0.005), while in hypertensive patients from 6.08 ± 3.54 to 6.80 ± 4.91 (p > 0.05). The left circumflex distal segment increased significantly in hypertensive compared to normotensive patients (F = 5.03, p = 0.03). The diameter increase was related to the baseline ET- 1 level (r = -0.67, p = 0.005). In conclusion, vasodilatation of the contralateral arteries during balloon inflation at the time of PTCA occurs mainly in the distal segments. The dilatation appears to be related to an increase in collateral filling. The recruitment of coronary collaterals during PTCA is associated with angina duration and increased c- GMP plasma levels. ET-1 has a weaker vasomotion effect on the coronary vasculature in hypertensive than in normotensive during PTCA.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Fragakis, Nikolaos
- Φραγκάκης, Νικόλαος
Subjects
dc:subject × 16Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/19954