Μηχανική υποβοήθηση ανεπαρκούσης καρδίας με τη τεχνική της αντιώθησης: πειραματική μελέτη

Abstract

dc:description

Mechanical support of the failing left ventricle is a well-established treatment modality for patients with end stage heart failure or cardiogenic shock. The Intraaortic Balloon Pump (IABP), with proven efficacy and wide availability, is the most often used device for this purpose. The Paraaortic Counterpulsation Device (PACD) with 100ml stroke volume, has been proven superior to the IABP and has been proposed as an alternative in cases of profound hemodynamic decompensation, when the IABP is ineffective, or when support is required for a prolonged period of time. In the present experimental study, the hemodynamic effectiveness of a small stroke volume PACD, presenting the advantages of ease of implantation and driving by a standard IABP console, has been compared to that of a 40ml IABP, in the setting of acute heart failure. Methods: In 8 experimental animals (pigs), left ventricular failure was induced with multiple ligations of small coronary arteries and propranolol, amiodarone and crystalloid infusion. The IABP was placed in the descending aorta and the PACD was implanted in the ascending aorta. Aortic pressures were recorded with and without mechanical assistance, provided by the IABP and the PACD, alternately. Cardiac output was monitored with the use of a transit time ultrasound flowmeter placed in the root of the pulmonary artery. Both devices were driven by the Datascope 96 driving system and were synchronized to the ECG in order to provide diastolic aortic augmentation. Results: Both devices significantly reduced the systolic aortic pressures (from 111 ± 18mmHg to 99 ± 16, p=0.000, and from 111 ± 18mmHg to 96 ± 22, p=0.000, for IABP and PACD, respectively) and end diastolic aortic pressures (from 82 ± 17mmHg to 73 ± 18, p=0.000 and from 82 ± 17mmHg to 50 ± 22, p=0.000, for IABP and PACD, respectively) in comparison to the baseline values. The PACD reduced the end diastolic aortic pressure more effectively than the IABP (reduction of 41.6 ± 18.9% vs 10.7 ± 10.2%, p=0.000). In addition, the two pumps provided significant peak aortic diastolic augmentation (from 82 ± 17mmHg to 110 ± 20mmHg, p=0.000 and from 82 ± 17mmHg to 115 ± 16mmHg, p=0.000, for IABP and PACD, respectively). The counterpulsation wave of the PACD was significantly greater (augmentation of 45.1 ± 22.1% vs 37.1 ± 16.1%, p=0.027). Both devices lowered the enddiastolic left ventricular pressure (from 24 ± 9mmHg to 19 ± 8mmHg, p=0.001, and from 24 ± 9mmHg to 18 ± 8mmHg, p=0.000, for the IABP and PACD, respectively), with a trend for PACD superiority (reduction of 24.2 ± 13.7% vs 19.7 ± 13.5%, for the IABP, p=0.064). The cardiac output was significantly and by the same amount increased by both pumps (from 34 ± 13ml/min/kg to 37 ± 13 ml/min/kg, p=0.009 and from 34 ± 13ml/min/kg to 37 ± 13ml/min/kg, p=0.028 for the IABP and PACD, respectively). Conclusion: The PACD, even with a smaller stroke volume, produces greater reduction in the enddiastolic aortic pressure and greater diastolic augmentation, than the standard 40ml IABP. The simplicity of its implantation together with the ability of the standard IABP driving systems to control its function make the small volume PACD an easily available, promising device for mechanical assistance of the failing heart.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2002

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Terrovitis, John
  • Τερροβίτης, Ιωάννης

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/20362

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Terrovitis, John; Τερροβίτης, Ιωάννης. Μηχανική υποβοήθηση ανεπαρκούσης καρδίας με τη τεχνική της αντιώθησης: πειραματική μελέτη. National and Kapodistrian University of Athens, 2002. http://hdl.handle.net/10442/hedi/20362