Back to search

University of Ioannina

Ανάπτυξη και αναλυτικές εφαρμογές νέων βολταμμετρικών χημικών και βιοχημικών αισθητήρων όζοντος

Abstract

dc:description

CHAPTER 1. In this chapter the development of a new amperometric biosensor for the determination of formaldehyde, is presented. The construction of the biosensor is based on the multi-membrane technique, which is consisted of an outer polycarbonate membrane and an inner cellulose acetate membrane. Alcohol oxidase has been immobilized onto a Nylon 66 membrane, which is placed between the two aforementioned membranes. The whole assembly is fitted onto the surface of a platinum working electrode with the aid of an elastic O-ring. The biosensor was mounted to a FI manifold and the enzymatically produced Η₂Ο₂ was monitored at +0.65 V (vs Ag/AgCl/KCl 3 M) at pH=7,0. Several types of membranes, such as HA (physical adsorption). Biodyne B (ionic affinity) and Immunodyne ABC (chemical binding), has been tested for the immobilization of the enzyme. The best results were retrieved for Biodyne B membrane. The response of the biosensor was tested against the pH, using a 0.05 M phosphate buffer solution in the pH range 5.5-8.5, revealing a maximum at pH 7.0. Methanol, ethanol, propanol and acetaldehyde were investigated as potent interferants. The results showed that only methanol and ethanol interfere at the proposed method, while propanol and acetaldehyde have no serious interference action. Under the optimum conditions, a linear calibration curve over the concentration range 0.01-1.0 mM HCHO, was constructed. Data fit the equation y = (142.1 ± 1.9) [HCHO, mM] + (1.9 ± 0.9) with a correlation coefficient r² = 0.9996 (n=5). The limit of detection (S/N 3) and the RSD of the method were calculated at 0.02 mM HCHO and 2.3% (n=9 for 0.5 mM HCHO), respectively. The stability of the biosensor is satisfactory and the system can be successfully used to measure more than 100 samples of 0.5 mM HCHO without need of intermediate recalibrations. The proposed biosensors, also, displayed very good storage ability when stored in the working buffer solution at +4 °C, if not in use. They retain their initial activity for more than 2 months. CHAPTER 2. An electrochemical method, based on the concept of a biosensor for the monitoring of ozone, is described for first time. The proposed method includes two parts: a selective sorbent for ozone, that is, eugenol and a formaldehyde amperometric biosensor, mounted to a flow-through cell. Via a 1,3-dipolar cycloaddition reaction ozone adds rapidly to the double bond of the allyl group of eugenol, which has been immobilized onto a hydrophobic C-18 reactor and the so produced formaldehyde is collected into the working buffer solution (sampler) and pumped to the detector. Ozone concentration was correlated with the peak current of the FI-curves, due to the enzymatically produced H²O², which was monitored at +0.65 V (vs Ag/AgCl/KCl 3 M) at pH 7.0. Under the optimum conditions, two calibration curves I/nA = f(μg mL⁻¹ O₃), one based on peak current signals of the FI-grams and the other based on the steady-state current outputs, over the concentration range 3-200 μg mL⁻¹ O₃, were constructed, applying the least-squares method. The equation for the FI-grams based straight line is y = (1.42 ± 0.01)(μg mL⁻¹ O₃) + (5.66 ± 0.99), with a correlation coefficient r²=0.9998 (n=8). The detection limit (S/N 3) and the RSD were calculated 2.1 μg mL⁻¹ O₃ and 0.74% (n=8 for 100 μg mL⁻¹ O₃), respectively. Correspondingly, the equation for the steady-state-based straight line is (2.23 ± 0.01) (μg mL⁻¹ O₃) + (0.92 ± 0.78) with a correlation coefficient r²=0.9998 (n=8). The detection limit (S/N 3) and the RSD were calculated 1.1 μg mL⁻¹ O₃ and 0.69% (n=5 for 100 μg mL⁻¹ O₃), respectively. The proposed method is interference free from other gases such as Ο₂, Ar, N₂, N₂O, NOCI, SO₂, NH₃ and CO₂, which were tested at concentrations >200-fold higher than that of 100 μg mL⁻¹ O₃, used for comparison. The analytical applicability of the proposed method was evaluated by determining the ozone concentration in synthetic gaseous samples, by using a stainless steel thermo stated chamber, being equipped with a ventilation system, fan and proper in/out-puts for enrichment, sampling or probing purposes. The results were in good agreement with those obtained by the Gastec system. CHAPTER 3. The first impedimetric sensor for ozone monitoring is described. The proposed method is based on the degradation of a lignin polymer film, due to the oxidative cleavage reaction of ozone, resulting in changes of the faradaic impedance. Glassy carbon working electrodes were modified with Lignin Organosolv (LO), by spotting 10μL of a 0.3 mg mL⁻¹ LO solution in acetone and left 12 h the solvent to evaporate in open air. Experimental conditions such as the solvent of LO, the concentration of the LO solutions, the amount of the volume spotted onto the electrode surface, the reaction medium and the reaction time were optimized by performing cyclic voltammetry and EIS experiments. The effect of 1) ozone on the electrochemical properties of bare GC electrodes, 2) oxygen (main component in the ozone stream) on the degradation of the lignin coatings and 3) sulphuric acid on the mechanical properties of the lignin films, were also investigated. CV and EIS experiments gave evidence that the obtained signals shown above are solely attributed to the ozonolysis reaction. A slight change of the electrochemical behaviour (decrease of capacitive current, increase of Rct) of the LO modified-GC electrodes was observed during the first 15 min, after the immersion of the sensors in the electrolyte solution (swelling of the polymer). To ensure a constant baseline all measurements were performed after a conditioning period of 30 min. All experiments regarding the ozonolysis reaction were carried out into 2.5 mL 0.001 M H2S04, with an O₃ flow rate of 0.25 L min⁻¹. The final concentration of ozone was achieved by adjusting the output of the ozone generator. Impedance spectra were recorded over a frequency range of mL⁻¹- 10⁵ Hz, using a single sinusoidal excitation signal, superimposed on +200 mV. Excitation amplitude of 10 mV (rms) was used throughout. All measurements were carried out in a solution of 10 mM K₃[Fe(CN)₆]/0.5 M KNO₃. Under the optimum conditions, a linear calibration curve over the range 50-250 μg O3, was constructed. Data fit the equation A = (0.36 ± 0.01) B + (-14.15 ± 1.36), where A = (ΔRct/Rci)x100 and B the amount of ozone in μg, with a correlation coefficient r²=0.9994 (n=5). The detection limit (S/N 3) and the RSD were calculated 11.3 μg Ο₃ and 2.1% (n=5 for 100 μg Ο₃), respectively. Lignin Alkali (LA) derivatives with tetraphenylphosphonium (TPP) and papaverine (PAP), were, also, tested as potent materials for the construction of impedimetric sensors for the monitoring of ozone. In addition, EIS data, has been approximated by a Randles equivalent circuit R(Q[RW]), in which the Cdi has been replaced by a constant phase element (CPE), with satisfactory results. The proposed sensor can be potentially applied for the monitoring of ozone in industrial workplaces or as a process gas in various technical and industrial applications.

Degree

thesis:*
Grantor dc:publisher
University of Ioannina
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Stergiou, Dimitrios
  • Στεργίου, Δημήτριος

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/20394

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Stergiou, Dimitrios; Στεργίου, Δημήτριος. Ανάπτυξη και αναλυτικές εφαρμογές νέων βολταμμετρικών χημικών και βιοχημικών αισθητήρων όζοντος. University of Ioannina, 2007. http://hdl.handle.net/10442/hedi/20394