Aristotle University Of Thessaloniki (AUTH)
Μορφομετρική ανάλυση του άνω τριτημορίου του μηριαίου οστού στον ελληνικό πληθυσμό
Abstract
dc:descriptionA detailed analysis of specific dimensions and shapes of the upper third of femur, in Greek population, was undertaken. Computed tomography was performed on 80 cadaver femora and extramedullary and intramedullary dimensions, which are necessary for femoral stem design in noncemented hip arthroplasties, were calculated with DICOM Viewer 2.1. image processing software. Each femur was sawn into horizontal slices corresponding to the same level as in CT and the above dimensions were manually measured by electronic caliper ruler. 1. The Extramedullary Parameters (Femoral Head Offset, Head Diameter, Head Center Height, Neck-Shaft Angle and Isthmus Position) were calculated and demonstrated great variability. 2. For medullary canal edge detection, it was found that instead of a constant threshold value, a local value must be computed separately for every image, depending on its density and structure, in problem areas. For the upper metaphysis, the threshold values ranged from 400-800 HU. 3. A dense calcar trabeculation has been observed in this study to modify the femoral canal, in the trochanteric region. This dense calcar septum was divided morphologically in three types. 4. A detailed analysis of the dimensions measured was undertaken. The shape of the metaphyseal canal was highly variable and there was a poor correlation between the dimensions of the diaphyseal and metaphyseal canal. The dimensions at the levels T-20 and T+20 (the supposed bone ingrowth region of a noncemented femoral stem) were poor correlated and thus the prediction of one dimension from another is unreliable. This means, that during hip arthroplasty, it is impossible, in practice, to achieve 100% cortical contact with the femoral stem, especially in the metaphyseal area. It seems reasonable that custom-made noncemented femoral stems are identical solutions for hip arthroplasties. 5. A suitable femoral stem for an individual patient should be selected according to the shape of the metaphyseal canal, which can be described by the Metaphyseal Canal Flare Index (MCFI). Primarily different stem designs could respond to differences in the mediolateral canal opening because the MCFI in the mediolateral and anterioposterior planes are well correlated. 6. There was a mean difference in intramedullary parameters between the CT images and manual measurements with an electronic calliper ruler. The differences were greater in the metaphyseal slices compared with the diaphyseal ones.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2007
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Αναστασόπουλος, Νικόλαος
- Anastasopoulos, Nikolaos
Subjects
dc:subject × 14- Μηριαίο οστό, Άνω τριτημόριο
- Εξωμυελικές παράμετροι
- Ενδομυελικές παράμετροι
- Μηριαίοι στείλεοι χωρίς τσιμέντο
- Ολική αρθροπλαστική ισχίου χωρίς τσιμέντο
- Upper third of femur
- Extramedullary parameters
- Intramedullary parameters
- Cementless femoral stem
- Cementless total hip arthroplasty
- Ιατρική και Επιστήμες Υγείας
- Βασική Ιατρική
- Medical and Health Sciences
- Basic Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/20432