Συγκριτική μελέτη της συγκρατητικής ικανότητας ορισμένων προκατασκευασμένων συνδέσμων ακριβείας και μαγνητών που χρησιμοποιούνται στη...
Abstract
dc:descriptionThe change in the retentive force of three types of prefabricated attachments and two magnets used in manufacturing overdentures has been studied by experiment. The strain put on the above units came from a crank apparatus with five pistons. There have been initial measurements of the retentive force and the following measurements were taken after completing 250, 500, 1,000, 1,500, 2,000, 2,500, 5,000, 7,500, 10,000, 25,000 and 50,000 strain cycles. The conclusions drawn by the above experiment are summarised as follows: 1. The retentive force of the prefabricated attachments and the magnets studied is different even for the units that belong to the same group. 2. The initial value of the retentive force of the prefabricated attachments studied is always higher than the value of the magnets. 3. Apart from the attachment Micro Fix, whose retentive force, after 50,000 strain cycles have been completed, has an average value which is higher than that of the small magnets, the remaining prefabricated attachments produce, in this stage, an average value of retentive force which is lower than that of the magnets, whether they are big or small. 4. The values of the retentive force of the prefabricated attachments studied, are reduced to the levels of the magnets, after completing a different number of strain cycles for each attachment (2,500 for the Zest Anchor, 7,500 for the Dablo and 25,000 for the Micro Fix). 5. The retentive force of the attachments Dablo, Micro Fix and Zest Anchor shows a clear change in value, already evident at the end of the first strain cycle. 6. After completing 50,000 strain cycles, certain elements used were completely destroyed (Zest Anchor 4 out of 10, Dablo 1 out of 10). 7. The surface of all the magnets which comes into contact with the follicles was oxidised, while the follicles showed practically no signs of wear. 8. The retentive force of the prefabricated attachments, after completing 50,000 strain cycles, were on a decrease; the decrease for the Dablo was in the order of 56.97%, for the Micro Fix in the order of 70.59% and for the Zest Anchor reached 89.94%. 9. The highest value of retentive force, that the Micro Fix and more specifically the element No IV reached, was 986 gr* and the average value of the initial measurements was 804.4 gr*, while the lowest value, that the element No VI of the small magnets reached, was 120 gr* and the average value of the initial measurements was 194.5 gr*. 10. Except for the magnets, whose retentive force remained practically unchanged during their strain, there have been changes in the retentive force of the remaining prefabricated attachments studied, in connection with th number of strain cycles carried out
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Λασκαρίδης, Ιωάννης
Subjects
dc:subject × 19- Προκατασκευασμένοι σύνδεσμοι ακριβείας
- Επένθετες ολικές οδοντοστοιχίες
- Συγκρατητική ικανότητα
- Σύνδεσμοι ακριβείας
- Μαγνήτες
- Συγκράτηση
- Κόπωση
- Κινητική προσθετική
- Retension
- Removable prosthodontics
- Prefabricated attachments
- Magnets
- Overdentures
- Retentive force
- Follicles
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/20440