In the context of this dissertation, a capillary optical immunosensor for the simultaneous determination of cardiac markers in the same sample was developed. This immunosensor was employed for the simultaneous detection of creatine kinase isoenzyme MB (CK-MB) and the subunit I of cardiac troponin complex (cTnI) in human serum samples. These molecules present highly cardiospecificity and are widely used in the clinical practice for the detection of acute coronary syndromes. The immunosensor was based on glass capillaries serving as optical waveguides, solid supports for the immobilization of bio-recognition molecules and immunoreaction tubes. The expected increase of the immunoreaction rate due to the high surface to volume ratio, and the low consumption of reagents were the reasons why the cylindrical geometry was selected for the fabrication of the immunosensor. A method for grafting of an ultra-thin Poly-(dimethylsiloxane) (PDMS) film on the internal surface of capillaries using an emulsion of the polymer was developed as the first step for the immobilization of biomolecules. This method is simple, faster than other literature methods, low cost, suitable for mass production, does not require the use organic solvents and can be applied in non-cylindrical surfaces. The PDMS-grafted capillaries combined the perfect optical properties of the glass with the high protein binding capacity of the polymer. In addition, they provided a more homogeneous immobilization of biomolecules as compared to glass capillaries chemically modified with 3-aminopropyl(triethoxysilane) (APTES), one of the most widely used glass modification agents. The simultaneous determination of CK-MB and cTnI was based on the creation of two distinct bioreactive bands on the internal surface of the PDMS-grafted capillaries. The creation of bands was accomplished by dispensing a suitable solution volume of the specific antibody raised against each cardiac marker at pre-defined parts of the capillary. This method was fast and easy to use compared to photolithographic and photochemical techniques, described in the literature for patterning of glass and plastic capillaries. The immunoassay of each cardiac marker was initially developed in microtitration wells so as to obtain a standard method for comparison of the analytical characteristics and the reliability of the developed dual-analyte immunosensor regarding the measurement of serum samples. The standard solutions were prepared in human serum using CK-MB and cardiac troponin complex (cTnICT). Cardiac troponin complex was employed since cTnI is mainly bound with subunit C and/or T when released to the blood circulation after myocardial infarction. For the determination of CK-MB, the capture monoclonal antibody employed, was raised against CK-MB, whereas the detection monoclonal antibody was raised against CK-BB, since this combination provided increased selectivity. For the determination of cTnI, the capture monoclonal antibody raised against cTnI was combined with two detection antibodies. The first one recognized a different epitope on cTnI molecule than the capture antibody, whereas, the second recognized an epitope on the cTnC molecule. The combination of the three antibodies permitted the detection of all forms of the analyte in blood at much lower concentrations compared to the rest of the antibody combinations examined. The enzyme horseradish peroxidase and R-phycoerythrin were tested as potential labels for the assays performed both in microtitration wells and in capillaries. In microtitration wells, the enzyme label was paired with a common chromogenic substrate, whereas in capillary immunosensor a signal amplification system based on a tyramide derivative conjugated with Alexa Fluor 488 (TSA-AF488) was adopted as substrate. Both methods were compared in terms of their analytical characteristics, employing the same label (R-phycoerythrine). The detection limits achieved using the multi-analyte capillary fluoroimmunosensor were significantly lower than those obtained from the respective fluoroimmunoassays performed in microtitration wells. Moreover, a reduction of 92% in the total analysis time was achieved with the proposed immunosensor compared with the respective assays conducted in microtitration wells. However, the combination of the enzyme label and the TSA-AF488 substrate permitted the detection of very low concentrations of cTnI and CK-MB in considerably shorter time and consequently was adopted in the protocol for the final validation of the immunosensor. .........................................

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2009

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Niotis, Aristeidis
  • Νιώτης, Αριστείδης

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/20707

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Niotis, Aristeidis; Νιώτης, Αριστείδης. Ανάπτυξη μεθόδου ταυτόχρονου ανοσοχημικού προσδιορισμού καρδιακών δεικτών με τη χρήση τριχοειδούς οπτικού ανοσοαισθητήρα. National and Kapodistrian University of Athens, 2009. http://hdl.handle.net/10442/hedi/20707