Χαρακτηρισμός δοσίμετρων οπτικά προτρεπόμενης φωταύγειας

Abstract

dc:description

In the present work popular TL dosimeters were studied in order to investigate if these dosimeters are also suitable for OSL dosimetry. The investigated materials were: Al2O3:C, KMgF3:Ce3+, CaF2:Tm, CaSO4:Mn and LiF:Mg,Ti. A bleachability study and preliminary measurements showed that two of these materials (Al2O3:C and KMgF3:Ce3+) are suitable for use in OSL dosimetry. The study was based in models for First, Second and General Order Kinetics. A computerized glow-curve deconvolution (GCD) method combined with a fitting process, were applied for the analysis of the experimental curves. In the first section of the thesis, the reconstruction of the real glow-curve shape of three kinds of Al2O3:C samples, with “narrow”, “wide” and “double” TL peak structures was performed successfully. The direct fit of the experimental, i.e. quenched glow-curve in the case of narrow TL glow-curve structures allows both reconstruction and evaluation of the thermal quenching parameters W, and C, yielding mean values of W=1.085±0.03 eV and C=(3.71±2.37)?1012, which are in excellent agreement with those given in literature. The reconstruction of composite TL glow-curve structures (“wide” and “double” glow curves) suffering from strong thermal quenching was also achieved. The stability of the relative peak height ratio as a function of the heating rate, in the case of double peak glow-curves, was attributed to the variation rate shape of the η(T) function, which increases rapidly, in absolute values, up to a maximum variation rate and then it decreases rapidly approaching to zero. In the next section of the study the correlation between the TL and LM-OSL signals of Al2O3:C was achieved. It was observed that the LM-OSL curve, especially in the case of the “wide” and “double” peak structure, consist of three components. The one to one comparison of each experimental glow-peak with the respective LM-OSL component showed that a quantitative and qualitative correlation between TL glow peaks and LM-OSL components exists. The comparison of the thermally quenched iii iv glow-peaks and LM-OSL components with the reconstructed values of the TL glow-peak implies that the LM-OSL signal is influenced by some kind of an optical quenching effect. At the final stage of the thesis, the bleaching decay constants of all individual TL glow-peaks of KMgF3:Ce3+ were evaluated by the residual TL method. It was found that the bleaching of each individual glow-peak takes place in three different rates; namely the fast, medium and slow rate. Each bleaching rate should be related to a unique OSL component with a specific decay constant in an OSL curve. However, some of these components can not be resolved during the CGD analysis of the OSL curve and as a result only six components can be used in order to perform a very good curve fitting to the LM-OSL curve of KMgF3:Ce3+

Degree

thesis:*
Grantor dc:publisher
Democritus University of Thrace (DUTH)
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Dallas, Georgios
  • Δάλλας, Γεώργιος

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/20784

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Dallas, Georgios; Δάλλας, Γεώργιος. Χαρακτηρισμός δοσίμετρων οπτικά προτρεπόμενης φωταύγειας. Democritus University of Thrace (DUTH), 2010. http://hdl.handle.net/10442/hedi/20784