National Technical University of Athens (NTUA)
Συμβολή της αιολικής διείσδυσης στην ευστάθεια των συστημάτων ηλεκτρικής ενέργειας
Abstract
dc:descriptionThe subjects of this thesis is modelling of wind generators for power system stability studies and their impact on power system stability, mainly short-term voltage stability and small-signal stability. Emphasis is given on Doubly Fed Asynchronous Generator (DFAG) which is the most popular scheme used today in wind generators. However, many conclusions refer to the other category of full-converter variable-speed wind generators. Different models for variable speed wind turbines were developed, appropriate for power system stability studies. The models were developed in Matlab/Simulink and in the frame of the power system simulation program WHSSP of the Electric Energy Systems Lab of NTUA. The various model assumptions are investigated, as well as their effect on stability. The models are used to investigate the low voltage ride-through capability of wind generators, a basic demand by transmission system operators. Modeling of the wind generator behavior during severe voltage sags, assuming low voltage ride-through capability is also investigated. Next, the contribution of variable-speed wind generators to short-term voltage stability is examined. Simulations in small test power systems and in the Evia network show that variable speed wind generators improve voltage stability compared to constant speed wind generators. A large part of the thesis concerns small-signal stability. First, the stability of a DFAG - infinite bus system is investigated. Speed control stability is analyzed and the DFAG response modes are specified. Using a DFAG model with detailed control loops, based on manufacturer data, it is ascertained that the reactive power control loop can introduce important dynamics. Stability of the specific control loop is analyzed and general rules are outlined. Next, a typical interconnected power system with local conventional power generation is investigated for various operating conditions and wind power penetration levels. As a general remark, the effect of wind power penetration is positive, i.e. damping of the interarea oscillation increases. For the cases where negative interaction occurs, it is shown that it can be avoided by the proposed tuning of the wind parks reactive power control loop. The impact of DFAG dynamic models on small signal stability of the Hellenic Interconnected system is also investigated in cooperation with the Hellenic Transmission System Operator (HTSO). At the examined operating point, a small positive impact on interarea oscillations is observed and appropriate tuning of the DFAG reactive power control loop is proposed, when necessary, to improve its stability. Finally, the thesis introduces and analyzes a power system stabilizer for wind generators (Wind PSS) to improve damping of interarea oscillations. The proposed controller is simple and similar to those proposed in the literature to emulate inertia in autonomous power systems.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2010
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tsourakis, Georgios
- Τσουράκης, Γεώργιος
Subjects
dc:subject × 20- Ευστάθεια συστημάτων ηλεκτρικής ενέργειας
- Αιολική ενέργεια
- Ασύγχρονη γεννήτρια διπλής τροφοδότησης
- Ανεμογεννήτριες μεταβλητών στροφών
- Ευστάθεια τάσης
- Ευστάθεια μικρών διαταραχών
- Διασυνδετικές ταλαντώσεις
- Αιολικός σταθεροποιητής ΣΗΕ
- Power system stability
- Wind power
- Doubly-fed asychronous generator
- Variable-speed wind generators
- Voltage stability
- Small signal stability
- Interarea oscillations
- Wind PSS
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/21035