Back to search

Aristotle University Of Thessaloniki (AUTH)

Ανάπτυξη μεθόδου προσδιορισμού εκπομπών από οχήματα με μέτρηση σε πραγματικό χρόνο

Abstract

dc:description

The need of better understanding and further improvement of the operation of modern low emission vehicles has drawn the attention on fast response time resolved emission measurements. The Constant Volume Sampling system (CVS), which is the main setup described by the European Union legislation for the sampling, dilution and measurement of motor vehicle tailpipe emissions over a certain driving cycle, can provide such data. The time resolution of the recorded data though is low due to design limitations of such systems. Transport delays in tubes, mixing and dispersion phenomena etc. are responsible for smoothening and distortion of the original emission signal. Aim of the current thesis is to develop a model to compensate for all these distortion sources, by taking into account the dynamic behaviour of the system. The problem was approached with purely mathematical tools derived from system theory. The CVS system was approached as a combination of different subsystems in series, that were individually modelled due to the specific design and flow characteristics of each. The parameters of each subsystem were estimated using measurements of the subsystem response to known and controlled artificial emission step inputs. The model of each subsystem was inverted and a specifically designed filter was applied to compensate for the noise of the inverted signal. The final model was designed such as to be applicable to already available or future measurements performed on the modelled setup. The model is also applicable on similar exhaust gas sampling and measurement setups with the need of specific system parameter identification measurements. The performance of the final model was evaluated compared against a sophisticated ultra fast response analyzer over a transient driving cycle. The model was proven to be able to reproduce the original signal with high accuracy. Furthermore, applications of the model on measurement devices that are used in series or parallel to the CVS setup were also presented. The methodology was able to reveal phenomena related to gaseous and particulate emission measurements that could not be revealed due to the limited time resolution of the original measurement output.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Geivanidis, Savvas
  • Γκεϊβανίδης, Σάββας

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/21274

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation