National and Kapodistrian University of Athens
Φαρμακολογικές και μηχανικές επιδράσεις στις διαταραχές του ακουογράμματος μετά υπαραχνοειδή αναισθησία
Abstract
dc:descriptionThis study was designed to evaluate the degree of cochlear dysfunction following spinal anesthesia administered through spinal needles of different shape and diameter.We studied 120 patients ASA I, II aged 55-85 years who underwent transurethral prostatectomy. The patients were randomly allocated to six groups in which the anaesthetic was administered through 22G Quincke, or 22G Whitacre, or 25G Quincke, or 25G Whitacre, or 26G Quincke, or 26G Atraucan. Spinal anaesthesia was administered through L3/4 or L4/5 interspace using lidocaine 5% 2ml. Audiometrie evaluation was made with pure tone audiometry. On the second postoperative day a new audiogram was performed. All results are presented as means (± SD). In all groups the preoperative minus the postoperative hearing levels for any change at each frequency were compared using the student's t-test p<0.05 was considered significant. In the group which received spinal anaesthesia via 22G Quincke or via 22G Whitacre needle an increase in the hearing threshold of 10-15dB was found at the lower and at the higher frequencies. In the group which received anaesthesia via 25G Quincke or via 25G Whitacre needle an increase in hearing threshold of 10-15dB was found at the lower frequencies. In the group which received anasthesia via 26G Quincke or via 26G Atraucan needle no significant change in hearing was observed. In comparing the 22G Quincke and the 22G Whitacre group there was a statistically significant hearing loss at 250Hz and at 500Hz. In comparing the 25G Quincke and 25G Whitacre group there was a statistically significant hearing loss at 125Hz. In comparing 26 G Quincke and 26G Atraucan needle there was no statistically significant hearing loss. In comparing the 22G vs 25G vs 26G Quincke needle group there was a statistically significant hearing loss at 125Hz, 250Hz, 500Hz, 1000Hz, 2000Hz, 3000Hz and at 4000Hz. In comparing the 22G Quincke vs 25G Whitacre vs 26G Atraucan needle group there was a statistically significant hearing loss at 125Hz, 250 Hz, 500Hz and at 2000Hz.The shape and the diameter of the spinal needle used for dural puncture are related to the degree of cochlear dysfunction.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2003
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Dimakopoulou, Antonia
- Δημακοπούλου, Αντωνία
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/21523