National and Kapodistrian University of Athens
Ανάπτυξη και μελέτη νέων χημειοφωταυγειομετρικών αναλυτικών τεχνικών
Abstract
dc:descriptionThis doctorial thesis is mainly focused on the study of new chemiluminescent reactions by the use of a batch system together with some variations of flow systems. By the use of a batch system for the prelimenary studies and the flow systems for further development, the possibilities to minimize the required time to attain the optimum conditions for the examined chemiluminogenic reactions, are considered. Also, several experiments are made in order to find new electrogenerated chemiluminescent reactions. The theoritacal part of this thesis presents the following subjects: A sort historicak review of chemiluminescence phenomena from ancient times until today. The principals and theoretical basis of chemiluninescence. The instrumentation which is used and optimazation of experimental parameters in chemiluminescent systems. A systymatic aproach of chemiluminescent reactions according with their common characteristics. Development of new chemiluminescent systems by the synthesis of new chemiluminescent probes. Applications of chemiluminescent reactions and a sort discuss about the benefits of chemiluminescent techniques over others optical techniques. The experimental part of this thesis deals with the following topics: A brief description of the instrumentation that is used during the elaboration of this thesis, which is consisted of a batch chemiluminometer, a continious flow and two flow injection analyzers and a photometer of electrogenerated chemiluminescence (chapter 2). The reactions of bilirubin with saome inorganic oxidants that lead to the emission of radiation. The ractions of bilirubin with sodium hypochlorite and N-bromosuccinimide are optimised, firstly with the batch chemiluminometer and after that with the continious flow and flow injection apparatus. It was found that the experimental parameters that affect the optimum conditions for every chemiluminescent reaction are similar between the several apparatus that were used. On the other hand, especially when the reactions are very fast, some parameters need to be reconsidered. The batxh system was found to have lower limits of detections, but the flow through systems had better repeatability. The reactions of bilirubin with these oxidants can not be used for the measurment of the analyte in real samples, because the alboumin, which usually coexists with bilirubin, emitts radiation under the same conditions (chapter 3). The effect of bilirubin oxidase on louminol, which results the emission of strong radiation from the reaction mixture. This radiation is reduced if bilirubin is added in the reaction mixture. This reduction in the emission can be used for the measurement of bilirubin, and the experimental parameters that affect this reduction are thoroughly examined. This methed presents very low detection limits (chapter 4). The behaviour of several compounds as for the emission of radiation, when they are examined in the electrogenerated chemiluminescent apparatus. Apart from louminol, which, as it was expected, emitts radiation, the other compounds that were tested did not emitt or emitted very weak radiation (chapter 5). The chemiluminometric method for the determination of trimetazidine in bilogical fluids and commercial formulations. The method is based on the chemiluminogenic reaction of trimetazidine with potassium permaganate in acid media. Acidic medium is established by polyphosphoric acid which enhances extensively the emission intensity, in comparisson with thw other common used acids. The method was developed with the batch system and reveal very low detection limit. Common excipients do not interfere severely an trimetazidine can be determined succesfully in commercial formulations. After extaction of trimetazidine from the real sample, the method can also be used in samples of serum and urine (chapter 6). The chemiluminescent behaviour of terbium (III). It was found that terbium (III) enhances the radiation which is emitted by the action of sodium ferricyanide on louminol, in alkaline media. This behaviour is also presented by several other metals, so the usefulness of this observation is limmited (chapter 7).
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Παλίλης, Λεωνίδας
- Palilis, Leonidas
Subjects
dc:subject × 20- Χημειοφωταύγεια
- Φωτόμετρα ψημειοφωταύγειας
- Χολερυθρίνη
- Οξειδάση χολερυθρίνης
- Λουμινόλη
- Τριμεταζιδίνη
- Πολυφωσφορικό οξύ
- Τερβιο ΙΙΙ
- Chemiluminescence
- Chemiluminometers
- Bilirubin
- Bilirubin oxidase
- Louminol
- Trimetazidine
- Polyphosphoric acid
- Terbium III
- Φυσικές Επιστήμες
- Χημεία
- Natural Sciences
- Chemical Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/21676