Back to search

National Technical University of Athens (NTUA)

Πειραματική και υπολογιστική μελέτη ροής σε μοντέλα αγγείων με παθοφυσιολογικά χαρακτηριστικά

Abstract

dc:description

There is strong evidence that mechanical stimuli constitute a major parameter triggering pathogenesis mechanisms related to blood vessel diseases like aneurysms and stenoses. Aneurysm being an abnormal local dilatation of the vessel lumen whereas a stenosis a narrowing of its cross section are both associated with complex blood flow patterns as well as spatial and temporal variations of viscous stresses and pressures. More particularly, wall shear stresses and wall static pressure distributions are of paramount importance influencing the functioning of the endothelial cells which play a significant role in the degeneration of the arterial wall either by weakening its structure or causing the formation of the so called atheromatic plaque. Since rupture of the aneurysm or the occlusion of a vital vessel can lead to significant problems to the health of a patient, it is an imperative need to understand the mechanisms which lead to these undesirable conditions in order to either avoid them or to better treat them. In the context of the present dissertation thesis, the above issues were examined by studying the flow behavior in three models, namely a) a symmetric tube dilatation simulating the flow in a fusiform aneurysm, b) a patient specific abdominal aortic aneurysm including its bifurcation, and c) a heated stenosis simulating the case of an inflammatory arterial stenosis. The velocity field was measured by using 2D PIV whereas for the case of the third model liquid crystal thermography provided details of the temperature field. Moreover, numerical predictions of the flow fields by using the commercial code FLUENT shed more light in regions where the above experimental techniques fail to work properly. In the first part of the current dissertation the flow field in an axisymmetric tube dilatation is studied under steady and unsteady inlet flow conditions employing 2D PIV and the commercial numerical code FLUENT. Experiment and numerical predictions are in good agreement providing similar trends and the same flow topology. For the steady case and for Re varying in the range 105-690, the recirculation zone length increases with Re, the flow reattachment line being displaced towards the exit of the model. In the unsteady case the flow rate was sinusoidal with a Womersley number 3.3. During early acceleration, a vortex ring is formed at the proximal part of the cavity and two stagnation points appear on the longitudinal axis of the model approaching each other as time progresses, eventually disappearing when the majority of the fluid particles changes direction. Wall shear stress shows high peaks at the distal end of the dilatation being proportional to the time dependent flow rate. The reattachment line travels along the wall, as well as the local pressure peak which is always located downstream of it. Massless particles released at various locations and time instants within a cycle are not trapped in the recirculation zone, being exposed to varying shear stress values. In the second part of this research the velocity field in a patient specific abdominal aortic aneurysm model including the aorto-iliac bifurcation was measured by 2D PIV. The geometrical details of aneurysm were revealed by CT angiography and a transparent replica was built using a 3D printer. Phase averaged velocities obtained in 14 planes reveal details of the flow evolution during a cycle with Womersley number 5.5, an average Re 191 and a peak Re 541. The aneurysm expanding asymmetrically towards the anterior side of the aorta causes the generation of a vortex at its entrance, covering the entire aneurysm bulge progressively before flow peak. The fluid entering the aneurysm impinges on the left side of its distal end, following the axis of the upstream aorta segment, causing an increased flow rate in the left (compared to the right) common iliac artery. High shear stresses appear at the aneurysm inlet and outlet as well as along the posterior wall, varying proportionally to the flow rate whereas two orders of magnitude lower shear stresses are present in the recirculation region. At the same regions elevated flow disturbances are observed, being intensified at flow peak and during the deceleration phase. At flow peak and during the deceleration phase a swirling motion is also present in the aneurysm due to the out of plane curvature of the aorta. ..............................................................

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Stamatopoulos, Christos
  • Σταματόπουλος, Χρήστος

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/21686

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Stamatopoulos, Christos; Σταματόπουλος, Χρήστος. Πειραματική και υπολογιστική μελέτη ροής σε μοντέλα αγγείων με παθοφυσιολογικά χαρακτηριστικά. National Technical University of Athens (NTUA), 2010. http://hdl.handle.net/10442/hedi/21686