The transfer of a free vascularized fibula graft in the subchondral region of the femoral head now is a widely accepted method for treating patients with osteonecrosis of the femoral head. In this study we are presenting the results of 28 osteonecrotic hips, which underwent free vascularized fibula graft transplantation using a patient-specific, aluminum alloy, aiming device for the optimal graft placement. The objective was to develop a computer-assisted design for an easier and accurateplacement of the graft to the necrotic area in the femoral head just below the subchondral bone. More specifically, the goal of this technique was to optimize the length and position ofthe fibular graft in the necrotic defect, and to diminish the xray exposure and preparation time. Thirty devices were manufactured. Two of these were excluded from the evaluation. One had extremely long lateral projections (ears) that did not permit the placement of the device on the outer surface of the greater trochanter and the other was the mirror image ofwhat it should have been, because of a technical error in the computer programming. There were 25 patients (28 hips), 15 males and 10 females, from 17 to 53 years old (mean age 32.25years) with an average 25.8 months follow-up results (from 9 to 43 months). In five cases the disease was associated with trauma, in one with alcohol abuse, in three with sick-cell disease, in 2 with idiopathic purpura, in 2 with pregnancy, in three with ALL, and finally in two with head trauma and ICU admission. Most of them were related with steroid use (42%). In three patients the disease was idiopathic. The severity ofthe disease at the time of the operation, according to the Steinberg classification was: stage II in nine hips, stage III in 7 hips, stage IV in 9 hips and stage V in 3 hips. These hips were compared with 28 hips which underwent fibular grafting by the same surgical team using conventional methods for graft placement. According to AP and lateral radiographs obtained postoperatively, only five patients(18,8%) operated on using the aiming device for fibular graft placement, had an inaccurate graft position. In the same group 6 patients had roentgenographic progression or clinical deterioriation of the disease in comparison with preoperative stage. Three ofthem (50%) had inaccurate placement of the graft. 60% ofthe patients with inaccurate placement of the graft had roentgenographic progression or clinical deterioriation of the disease. On the contrary only 7 hips (25%) of the patients operated on using the conventional method had accurate placement of the graft. In this group 13 hips had a roentgenographic progression of the disease. The aiming device seems to be an accurate method: 82% of the patients had an optimal graft placement while the graft placement during conventional graft surgery leads to good graft placement in only 25% of the hips). The aiming device diminishes Xray exposure during canal preparation: 13,61±6,86 seconds when the aiming device was used and 24,3±14,5 seconds when the conventional method was used. The aiming device also diminishes the time required for preparation of the canal: the mean time for the conventional method was 44.25 minutes but it was only 28.6 minutes in patients using the aiming device. For the follow up period, the aiming device compared with the conventional method, seems to improve roentgenographic and clinical results. Further follow-up is needed for better evaluation of these results

Degree

thesis:*
Grantor dc:publisher
University of Ioannina
Year dc:date
2005

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Κωστόπουλος, Βασίλειος
  • Kostopoulos, Vasileios

Subjects

dc:subject × 8

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/21958

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Κωστόπουλος, Βασίλειος; Kostopoulos, Vasileios. Άσηπτη νέκρωση μηριαίας κεφαλής, χειρουργημένη με μεταφορά αγγειούμενης περόνης: ιδανική τοποθέτηση του μοσχεύματος με εξατομικευμένο μεταλλικό πρόθεμα και τεχνολογία CAD - CAM. University of Ioannina, 2005. http://hdl.handle.net/10442/hedi/21958