National and Kapodistrian University of Athens
Διαδερμική οστική βιοψία υπό τον αξονικό τομογράφο: τεχνική, ακρίβεια και αποτελεσματικότητα της μεθόδου
Abstract
dc:descriptionPURPOSE: To present the diagnostic approach of bone lesions with percutaneous trephine biopsy under Computed Tomography(CT) guidance. To describe the procedure, to determine the specificity, the accuracy and its possible complications. MATERIAL AND METHOD: In a 27-month period 296 percutaneous skeletal biopsies were performed under CT-guidance in 287 patients (176 men and 111 women, age range 11-86 years, 171 outpatients and 116 inpatients). The biopsies were performed under local anesthesia. Forty five to 60min before the procedure all patients received an analgesic treatment consisting of 3mgr bromazepam per os and 0,05gr pethidine hydrochloride IM. In all biopsies 1-3 specimens were obtained with the trephine biopsy - 228 - set (14gauge/12cm & 19,5cm). In 260 biopsies 1-4 specimens were obtained with the automated biopsy needle (16gauge or 18gauge/15cm). In 99 of them material for cytological evaluation was received with CIBA 20gauge & 22gauge/15cm needle. Finally, in 114 biopsies material for microbiologic evaluations and cultures was received and in 11 material for haematological examination. RESULTS: Only the 272 patients who had a 6month follow-up participated in the study. The 15 patients with no monitoring were excluded. The results and the statistic analysis were related with 280 biopsies. The total results from the overall analysis of the biopsy material were of great specificity in 71.4%. Only in 1.8% there was no diagnosis. The highest per cent of great specificity results came from the histological tests (61.4%), the cytological results were of great specificity in 9.8%, the cultures’ results in 41.5% and the haematological results in 45.5%. The accuracy was 98.9% for the histological evaluation, 91.4% for the cytological evaluation and 94.8% for cultures. The high percentage of specificity (p<0,001) and accuracy (p=1.00) in histological results depended exclusively on the number of the received specimens. The anatomic location of the lesion and its structure were of no statistic significance. Three minor complications were noticed, consisting of local hematoma (1%). CONCLUSION: The percutaneous bone biopsy under CT-guidance is a safe procedure with great specificity and accuracy, depending on the number of specimens received.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2006
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Mylona, Sofia
- Μυλωνά, Σοφία
Subjects
dc:subject × 8Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/22378