National and Kapodistrian University of Athens
Μελέτη παραμέτρων αιματικής ροής με αιμορροόμετρο laser doppler σε χρόνια αρτηριακή απόφραξη
Abstract
dc:descriptionAim: The clarification of the relationship between the parameters of blood flow (defined with bloodless measurements using the Laser Doppler Blood Perfusion Monitor) and the chronic obstructive arterial disease of the lower limbs and its different stages (specified by measuring the ankle-brachial pressure index, A/B). Patients and methods: During the period between April 1999 and July 2000, 82 lower limbs have been studied with the use of Laserflo BPM². 42 were diagnosed as having chronic obstructive arterial disease (A/B<1) while the other 40 belonged to healthy subjects (A/B≥1). The measured parameters of blood flow included Flow, Volume and Velocity of the microcirculation. The measurements were conducted during rest and during the reactive hyperemia test. The measurement of the blood flow parameters lasted 2 minutes in the resting phase and 2 minutes in the reactive hyperemia phase. The obstruction of the arterial blood flow, in order to achieve reactive hyperemia, lasted for 3 minutes and the overall duration of the procedure was approximately 20 minutes. There were no complaints reported by the subjects, except for a slight discomfort caused to some of them during the reactive hyperemia phase. Results: The results were subjected to statistic analysis and evaluation which showed that: A. The chance that a subject is suffering from chronic obstructive arterial disease of the lower limbs rises to more than 90%, when the period of time elapsing until peak blood flow (TPF) is achieved in less than 34 seconds. B. The chance that a subject is suffering from chronic obstructive arterial disease of the lower limbs when TPF exceeds 34 seconds is 75%. C. When TPF ranges between 34 and 45 seconds, it is not certain whether the subject is suffering or not from chronic obstructive arterial disease of the lower limbs and even when he is, the chance that A/B is less than 0.7 is very small (only 14%). D. When TPF exceeds 34 seconds and the minimum recorded velocity of the microcirculation during reactive hyperemia (RVELOC MIN) exceeds 0.21mm/sec, the chance that a subject is suffering from a moderate form of chronic obstructive arterial disease of the lower limbs (0.7<A/B<1) is approximately 70%. Conclusion: A relationship does exist between some of the parameters of blood flow (defined with bloodless measurements, using the Laser Doppler Blood Perfusion Monitor) and chronic obstructive arterial disease of the lower limbs. This procedure allows the discrimination between a healthy (A/B≥1), a moderately ill (0.7<A/B<1) and a severely ill (A/B<0.7) subject, with a more than 70% success rate. However, technical difficulties and other disadvantages limit its usefulness as a clinical diagnostic tool.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2002
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Στρατηγός, Παναγιώτης
- Stratigos, Panagiotis
Subjects
dc:subject × 15- Μικροκυκλοφορία
- Χρόνια αρτηριακή απόφραξη
- Σφυροβραχιόνιος δείκτης πίεσης Α/Β
- Αντιδραστική υπεραιμία
- Χρόνος για μέγιστη ροή
- Microcirculation
- Laser doppler
- Chronic arterial obstruction
- Ankle-brachial pressure index A/B
- Reactive hyperemia
- Time to peak flow (TPF)
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/22416