National and Kapodistrian University of Athens
Ανάπτυξη και αξιολόγηση τριχοειδούς οπτικού ανοσοαισθητήρα φθορισμού για τον ταυτόχρονο προσδιορισμό διαφορετικών ουσιών στο ίδιο δείγμα
Abstract
dc:descriptionΤhis work deals with the development of a multi-analyte capillary optical immunosensor. The immunosensor was employed for the simultaneous determination of three different pesticides (mesotrione, hexaconazole and pirimicarb) in samples of commercially available bottled natural waters. Τhe immunosensor was based on capillary tubes that served as signal transducers, as the solid-phases for the immobilization of the immunoreagents and as the immunoreaction vials. The reasons that lead to the selection of the capillary geometry for the fabrication of the immunosensor were: i) the expected increase in the reaction rate due to the increased surface to volume ratio and the restricted influence of the diffusion owing to the small internal diameter of the capillary and ii) the reduced consumption of immunoreagents. Plastic material was chosen for the preparation of single use capillaries, due to the simplicity of immunoreagents immobilization it offered and the expected reduction in fabrication costs. Poly-(methyl-pentene) was found to be the most suitable plastic material due to the low auto-fluorescence it presented, compared to other plastic materials tested, and its satisfactory protein adsorption characteristics. Fluorescein was chosen as the most suitable label based on the criterion of higher signal to background ratio that depends on the selected material for the fabrication of the capillaries, the labeling procedure and the fluorescence characteristics of each label. The simultaneous determination of the different analytes was accomplished through the formation of different immunoreaction bands in the internal surface of the capillary that were equal in number with the determined analytes. The formation of these bands was achieved by injecting the appropriate volume of the immunoreagent in pre-determined positions of the capillary, since this methodology provided more symmetrical peaks compared to that based on the successive aspiration of immunoreagents and inert protein, whereas it was also faster and easier. The geometric characteristics of the immunoreaction bands were optimized, so as to achieve the highest possible signal and avoid cross-talk effects. The immunoassay of each pesticide was developed in microtitration wells, so as to serve as comparison method for the results obtained using the triple-band immunosensor developed for the simultaneous determination of all three pesticides. Prior to the development of triple-band immunosensor, each analyte was determined separately by developing the single-band immunosensor. The conditions chosen for the single-band immunosensor were also employed for the triple-band sensor, since it was found that each immunoassay performed in the internal surface of the capillary immunosensor is independent from the rest. Detection limits and working ranges for all three analytes were the same for immunoassays performed either using microtitration wells or single- and triple-band immunosensors. In addition, the performance of recovery and dilution tests proved the accuracy of measurements using single- and triple-band immunosensors. ...............................................................................................
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2003
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Mastiiadis, Christos
- Μαστιχιάδης, Χρίστος
Subjects
dc:subject × 19Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/22697