Back to search

National and Kapodistrian University of Athens

Εφαρμογές τεχνικής χρωματογραφίας HPLC με ανιχνευτή σκέδασης ακτινοβολίας στον έλεγχο γλυκοσιδών αντιβιοτικών

Abstract

dc:description

Evaporative Light Scattering Detector (ELSD) is increasingly being used in LC as a quasi-universal detector eliminating the need for derivatization of non-absorbing analytes. Its ability to perform quantitation of substances with lack of standard material, since it shows nearly equal response factors for molecules with about equal molecular mass and similar structure formula, is well-established. In the field of pharmaceutical analysis, it has already been proposed as an effective alternative for the determination of, among others, cyclodextrins, polyethylene glycols, products of combinatorial and parallel synthesis and inorganic ions, including sulfates in gentamicin raw material. Aminoglycosides contain one or more aminosugars, such as glucosamine or neosamine, linked by glycoside linkages to a basic (amino or guanidino) 6-membered carbon ring (eg. streptidine or streptamine). They may be classified as broad spectrum-antibiotics with greater activity against gram-negative than gram-positive bacteria. Various HPLC methods have been proposed for the determination of aminoglycosides but due to the low UV absorptivity and the absence of native fluorescence, pre-column or post-column derivatization is required. HPLC methods with electrospray ionization/ion-trap tandem mass spectrometry, pulsed electrochemical detector and laser-based polarimeter have also been reported. In this study novel HPLC-ELSD methods with Waters C18 Spherisorb ODS-2 4.6?250 mm analytical column were developed and validated for the direct determination of: a) the four major gentamicins, b) neomycin, c) kanamycin A and kanamycin B and d) tobramycin along with the inorganic co-ion (sulfate). No derivatization step was required, and the applicability of the developed methods to various matrices (raw materials, formulations, bacteria culture medium, animal feedings, plasma and urine) was examined. Gentamicin (sulfate) mainly consists of four closely related components designated as C1, C1a, C2 and C2a. The lack of reference standard material makes the direct quantitation of individual components quite difficult, and the chemical analysis is limited to the determination of the relative fraction of each component from the area of the chromatographic peaks (which is influenced by the differences of the absorptivity among the various components derivatives). In this study Multivariate Simplex algorithm was applied for the final optimization of the composition and the flow rate of the mobile phase. Six response variables were evaluated (peak areas, precision, asymmetry, resolution, retention time of the first and the final peak). The algorithm stopped after 16 experiments. Best results were obtained using a mobile phase of H2O/MeOH/ACN 990/5/5 containing 0.88 ml TFA and 35 mg TCA per liter, in an isocratic mode at a rate of 1.1 ml/min. After univariate optimization evaporation temperature was selected to be 50 oC and pressure of carrier gas (N2) 3.0 bar. Gentamicin components C1a, C2, C2a and C1 are eluted at 4.6, 5.9, 7.1 and 8.7 min, respectively with asymmetry factor 1.4-2.0 and good resolution (Rs > 1.5). Logarithmic calibration curves (from 4-7 to 50-90 μg/ml) was obtained for each component (r > 0.999). Limit of detection was ranged from 4 to 7 μg/ml and precision (%RSD, n= 4) 0.4-2.2. Kanamycin (sulfate), another aminoglycoside antibiotic available at high purity, is eluted at 3.2 min and it is well-separated from gentamicin C1a (R=1.6). The equivalence of responses of gentamicin components and kanamycin to ELS detection (proven by t-test) allows the use of kanamycin as standard substance for the direct quantitation of gentamicin components. Also the simultaneous determination of sulfate was feasible (LOD= 1.4 μg/ml, %RSD= 0.18, r> 0.994). The proposed method was applied for the determination of gentamicin in pharmaceutical formulations (injection, eye drops and cream). The only pretreatment step was the appropriate dilution with the mobile phase, except for cream, which a liquid - liquid extraction was required. Dilution experiments revealed the absence of interference from exipients (constant and proportional errors) and recovery from standard addition experiments was ranged from 99-102% and precision (%RSD, n= 3) 1.4-2.3. ....................................................................................................................................................

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2004

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Megkoulas, Nikolaos
  • Μέγκουλας, Νικόλαος

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/22699

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Megkoulas, Nikolaos; Μέγκουλας, Νικόλαος. Εφαρμογές τεχνικής χρωματογραφίας HPLC με ανιχνευτή σκέδασης ακτινοβολίας στον έλεγχο γλυκοσιδών αντιβιοτικών. National and Kapodistrian University of Athens, 2004. http://hdl.handle.net/10442/hedi/22699