Aristotle University Of Thessaloniki (AUTH)
Συμβολή στη μελέτη της αντικειμενικότητας της εκτίμησης του ύψους της φατνιακής ακρολοφίας με τη χρήση του λειτουργικού προγράμματος Denta - Scan σε ασθενείς που εξετάζονται σε αξονικό τομογράφο
Abstract
dc:descriptionImplant planning requires the acquisition of cross-sectional images to estimate the available bone support. Software was developed to produce virtual panoramic and cross-sectional images by reformatting axial CT slices. Computed tomography is regarded as the modality of choice for detailed planning prior to the surgery itself. Computed tomography does not replace a series of imaging studies but complements them with images which cannot be produced by them. No single radiographic procedure provides ideal images for all steps in implant planning process. The dentist who is contemplating impants for his patients must be able to categorize the imaging options available for pre-surgical planning by their availability, cost, radiation dose, accuracy and other advantages and disadvantages. Dental panoramic tomography creates a very useful overview of the patient’s maxillary and mandibular dentition. Conventional tomography (Scanora) is ideal for evaluation of a single implant site. If the entire jaw is to be imaged and in the case of more complicated surgery computer tomography is the modality of choise. The purpose of this paper was to evaluate the objectivity of the estimation of the dental alveolus crest bone height, when Denta-Scan program is used in patients examined with computed tomography. On the whole, 51 patients and 59 partially edentulous jaws were examined. During the examination the patients had a silicon bite-block containing a known dimension aluminium object. This object was parallel to the alveolar crest bone in the oral cavity. The width of the object was measured in the cross-sectional reformatted images. The measurements were carried out by means of compasses in the scale of the radiographic film. They were performed by two examiners who measured twice each. The reliability of each and the agreement between them were measured. It was demonstrated that slight breathing and swallowing movements affect the sharpness of the image which in turn affects the measurement accuracy. The importance of personal examiner intervention in measurement accuracy was shown. What was also shown was the disadvantage of the measuring method itself on the radiographic film as regarding the plane of 1/10 of millimeter. The upper limit error for Denta-Scan cross-sectional reformatted images was estimated at 0,2 mm. The measurement accuracy is not affected by the kind of jaw (maxillary or mandibular) but by the edentulous areas. It presents a statistically significant error in the posterior areas rather than in anterior areas. It was established from the results that the reformatted images are perpenticular to the plane designated by the curve drawn to the axial slice and not to the surface of alveolar crest. That is why the choice of the points the curve crosses, are of critical importance.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2004
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Papadeli, Chrysa
- Παπαδέλη, Χρυσή
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/22745