Back to search

National and Kapodistrian University of Athens

Συγκριτική μελέτη μεταξύ μαστογραφίας και μαγνητικού συντονισμού σε ασθενείς με καρκίνο του μαστού

Abstract

dc:description

Τhis study was completed in three consecutive stages: Stage A: performed at the Radiology Department of Athens University, "Areteion" Hospital, between May 1993 and May 1994. The aim was to assess the feasibility of magnetic resonance mammography (MRM) in a 0.5 Tesla system (without a dedicated breast coil or post-processing software) and to identify criteria of differential diagnosis between breast cancer (BC) and benign lesions. In total, 35 women with already known or very probable BC and with a recent X-ray mammogram (MG), had undergone MRM a few days before surgery. The main conclusions were: a) MRM is feasible in a 0.5 T magnet, but without a dedicated coil its spatial resolution is limited and without dedicated post-processing software its evaluation is time-consuming, b) MRM is more accurate than MG for evaluating the extent of BC, c) there is a considerable overlap of the imaging features of BC and benign foci. Stage B: performed at "Hygeia" Hospital (Athens, Greece), between July 1994 and August 1999. It was designed to prospectively evaluate the previously defined criteria of differential diagnosis between BC and benign lesions. 95 women with variable suspicion of BC, based on clinical examination or MG findings, had undergone MRM in a 0.5 T system of newer technology, equipped with dedicated breast coil and post-processing software. The sensitivity, specificity, PPV, NPV and accuracy of MRM were found 91%, 72%, 51%, 96% and 76% respectively, compared to 59%, 55%, 30%, 80% and 51% of MG. The combination of MRM and MG provided a 100% sensitivity for BC detection, regardless of the histological type. Stage C: performed at "Hygeia" Hospital (Athens, Greece), between September 1999 and December 2007. It was a prospective study, designed to compare MRM and MG in various subgroups of patients. 725 women were included. All MRM examinations were performed in a 1.5 T system with a dedicated coil, power injector and post-processing software. The sensitivity, specificity, PPV, NPV and accuracy of MRM were found 97%, 78%, 56%, 99% and 83% respectively, compared to 81%, 57%, 34%, 91% and 62% of MG. The combination of MRM and MG provided a 100% sensitivity for BC detection, regardless of the histological type. Conclusions: a) MRM should be performed in high field (1.5 T) magnets, equipped with dedicated coil and software and with the use of a power injector, b) standarization of the technique and diagnostic criteria is mandatory, c) the sensitivity and NPV of MRM for infiltrative BC are practically 100%, but one must be carefull with the diffuse type of infiltrative lobular BC which can have an atypical appearance, d) DCIS cases can be missed by MRM, e) MRM has a moderate specificity, f) MRM can be useful for defining the exact extent of BC (especially in dense breasts), for differentiating scar from tumor relapse, for screening high-risk patients, for assessing residual tumor after a recent lumpectomy, for evaluating patients with metastatic cancer of uknown origin and, generally, in any case with ambiguous findings on MG or clinical examination.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Roussakis, Arkadios
  • Ρουσάκης, Αρκάδιος

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/22972

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Roussakis, Arkadios; Ρουσάκης, Αρκάδιος. Συγκριτική μελέτη μεταξύ μαστογραφίας και μαγνητικού συντονισμού σε ασθενείς με καρκίνο του μαστού. National and Kapodistrian University of Athens, 2008. http://hdl.handle.net/10442/hedi/22972