National and Kapodistrian University of Athens
Οι νεώτερες μέθοδοι στην αντιμετώπιση της πλήρους πάχους οπής της ωχράς κηλίδας
Abstract
dc:descriptionPurpose: To compare the anatomical and functional results of patients with full thickness macular hole (FTMH) operated with vitrectomy and removal of the internal limiting membrane (ILM) with and without staining with indocyanine green (ICG) and to analyze the role of ICG in the possible postoperative complications. Material-Method: Forty five eyes of 45 patients with FTMH stage ll-IV were operated with pars plana vitrectomy. The patients were divided in 2 groups. Group A included 35 patients who had the ILM removed after staining with ICG and group Β included 10 eyes that had the ILM removed without any staining. All eyes had a preoperative and postoperative examination with Optical Coherence Tomography (OCT). Results: The mean age in group A was 62±11.7 years while the mean age in group Β was 59.9±14.1 years (p=0.506). The mean follow-up period was 10.9±11.9 months (3-49). The mean preoperative visual acuity (VA) was 0.13±0.09 ranging from counting fingers to 5/10 (group A 0.13±0.1 [counting fingers to 5/10, group Β 0.145± 0.06 [1/20 to 2.5/10], p=0089). Closure of the hole with 1 operation was achieved in 42 (93.3%) eyes (group A 33 eyes [94.3%], group Β 9 eyes [90%], p=0.654). The mean postoperative VA was 0.36±0.22 ranging from counting fingers to 9/10 (group A 0.35±0.24 [counting fingers to 9/10], group Β 0.38±0.15 [1 5/10 to 7/10]). There was a statistically significant difference between the preoperative and postoperative VA in both groups (group A p=0 group Β p=0.002). We did not observe pigment epithelium changes or pigmentation of the macula postoperatively in any case. No relation was found between the postoperative VA and the retinal thickness at the foveola as well as at the central 1-mm-diameter circle of the fovea in both groups as measured by OCT. Conclusions: VA improves significantly after successful surgery for FTMH ICG appears to be safe without any obvious signs of retinal toxicity. In our study we did not observe any differences in the anatomical and functional results between the staining or not of the ILM with ICG. No relation was found between the postoperative VA and the retinal thickness at the fovea.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Grigoropoulos, Vlasios
- Γρηγορόπουλος, Βλάσιος
Subjects
dc:subject × 16Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/23020