Back to search

National Technical University of Athens (NTUA)

Εμβιομηχανική της σπονδυλόμενης σπονδυλικής στήλης: μελέτη των εμφυτευμάτων της οσφυϊκής μοίρας της σπονδυλικής στήλης, με στόχο την αξιολόγηση - τεκμηρίωση της εμβιομηχανικής τους επάρκειας και αποτελεσματικότητας

Abstract

dc:description

The purpose of the present PhD Thesis is the study and deeper understanding of spinal instrumentation mechanical behavior, as well as the investigation of a broad spectrum of parameters that influence their biomechanical efficiency. In particular the study was focused on pedicle screw internal fixation of the lumbar spine. For the realization of the research both experimental procedures and numerical simulations were employed. The combination of experiment and simulation helped significantly enhancing the efficiency and the accuracy of the study. Pedicle screws are sophisticated parts of composite structures (spinal fixation systems) which exhibit complex mechanical behaviour. The safest way to address this complexity is through the well-known scheme of analysis and synthesis. In order to optimize the mechanical behaviour of pedicle screws one should first identify its constitutive aspects, study each one of them separately and at the end synthesize the general solution from the partial ones. In this direction, it can be noted that pedicle screws have a dual purely mechanical role: provide stability to the spinal fusion system by rigidly gripping itself into the vertebra and carry high loads perpendicularly to its axis. Based on the above the present study focused as a first step to the investigation of the factors affecting the strength of the pedicle screw fixation into the vertebra. The screws were studied under pure pullout loads. This load case was chosen because it helps separate the strength of the screw’s gripping from its mechanical behaviour under loads applied normally to its axis. In particular the parameters studied were the screw insertion technique followed by the surgeon, the material properties of the screw, the geometry of the screw and its relative dimensions to the vertebra. First of all, the pullout phenomenon was studied experimentally and the influence of the screw insertion technique was evaluated. Typical commercial self-tapping pedicle screws were inserted into blocks of synthetic cancellous bone (simulating osteoporotic cancellous bone) following different insertion techniques and their pullout force was measured. The screw was inserted into previously prepared holes of different sizes, either threaded or cylindrical; in order to conclude whether an optimum size of thepilot-hole exists and whether tapping can increase the pullout strength. The case where the tapping is performed using another screw was also studied. The results of this study indicated that a screw’s fixation strength can be improved by under-tapping of a pilot-hole either using a tap or another screw. As a next step the experimental results were used for the design, calibration and validation of a finite-element model. Special attention was paid to the accurate simulation of the failure inside the host material under shear. For this purpose, a bilinear cohesive zone material model was adopted, controlling the mode-II debonding of neighbouring elements in the vicinity of the screw. Comparison between experimental and numerical results proved that the implementation of this approach can significantly enhance the accuracy of the numerical simulation of a screw’s mechanical behaviour under pure pullout loads. The numerical model was used for the parametric study of various screw design parameters affecting the pullout performance of a cylindrical pedicle screw. It was concluded that the screw’s elastic modulus can significantly influence the mechanical behaviour of a bone screw. Bone screws with elastic modulus similar to the bone appear to produce a more uniform stress distribution pattern around them. As far as the geometry of the screw is concerned it was concluded that the major parameters affecting the screw’s fixation strength are its outer radius and its purchase length. The thread depth appeared to have little influence itself on the screw’s pullout force but to affect the pullout force dependence on the rest of the geometry parameters studied. In particular, in the case of screws with relatively “deep” threads the pullout force is practically independent from the value of the thread inclination and pitch. On the contrary in the case of screws with relatively “deep” threads the pullout force increases with increasing inclination and decreasing pitch. During this numerical study the phenomenon of hosting material pretensioning due to radial compaction was ignored. Radial compaction of the hosting material is observed when the screw is inserted into a hole that is smaller than the screw itself, as it happens in the case of conical screws or screw insertion with under-tapping of the cylindrical guiding hole or without any tapping at all (self-tapping). Radial compaction results in the development of a complex stress field around the screw (before the initiation of the pullout procedure) which is unknown and cannot be calculated analytically. In this context the finite element model previously presented was modified in order to incorporate the ability to produce this complex stress field during a load step that precedes the pullout. This finite element model was used for the parametric investigation of conical screw’s conical angle to its pullout strength. It was concluded that a screw’s pullout force increases with increasing conical angle until it reaches a critical value. In case the conical angle is further increased the pretension induced damages the screw’s hosting material and the pullout force value is decreased. In order to investigate the influence of the vertebra’s inhomogeneity to the screw fixation strength a numerical study was realized. During the design of the numerical model the variation of the mechanical properties of the vertebra was taken under consideration. Based on published bone mineral density measurements the finite element model of the vertebra was divided into three materials with different mechanical properties. The finite element model was employed for the parametric study of the relative pedicle screw vertebra dimensions. The parameters considered were the penetration ratio, i.e. the ratio of the screw length divided by the distance from the posterior pedicle entrance site to the anterior vertebral cortex, and the filling ratio, i.e. the ratio of the major diameter of the screw divided by the transverse diameter of the pedicle. The control of these parameters was performed by modifying the size of the vertebra and not of the screw. This way the influence of the relative size was separated from the influence of the screw geometry. The results of the parametric study highlighted the importance of the strong materials of cortical and subcortical bone. As far as the filling ratio is concerned it was concluded that an optimal value exists. During the last step of the analysis the mechanical behaviour of a complete spinal fixation system consisted of four pedicle screws and two titanium rods was studied under bending and torsional moments. First of all the mechanical behaviour of the spinal system was studied experimentally following the vertebrectomy model and its stiffness in flexion-extension and torsion was measured. The results indicated that the spinal fixation system is stiffer in extension than it is in flexion and that without the extra support of a crosslink it is rather unstable in torsion. The experimental procedure for the measurement of the bending and torsional stiffness was simulated with a three dimensional finite element model. The experimental results were used for the verification and validation of the accuracy of the numerical model, which was finally employed for the investigation of the stress fields developed into the spinal system during flexion-extension and torsion. The results indicated that the strongest stress concentrations develop on the screw surface at the transition area between the screw’s body and head.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Chatzistergos, Panagiotis
  • Χατζηστέργος, Παναγιώτης

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/23045

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Chatzistergos, Panagiotis; Χατζηστέργος, Παναγιώτης. Εμβιομηχανική της σπονδυλόμενης σπονδυλικής στήλης: μελέτη των εμφυτευμάτων της οσφυϊκής μοίρας της σπονδυλικής στήλης, με στόχο την αξιολόγηση - τεκμηρίωση της εμβιομηχανικής τους επάρκειας και αποτελεσματικότητας. National Technical University of Athens (NTUA), 2010. http://hdl.handle.net/10442/hedi/23045