Back to search

National Technical University of Athens (NTUA)

Στοιχειακές και ισοτοπικές αναλύσεις ουρανίου σε υγρά δείγματα

Abstract

dc:description

The nuclear engineering laboratory of the ntua is involved in uranium analysis by using various measurement techniques. In order to extend the laboratory’s analytical capabilities, a kinetic phosphorescence analyser kpa-11 was added to the methods employed, to conduct phosphorimetric determination of uranium concentration in liquid samples. The present thesis describes the study, development, application and optimisation of practices that constituted the phosphorimetric apparatus of the laboratory a reliable technique for determining uranium concentration in liquid samples. After reviewing the theoretical principles governing phosphorimetry and becoming familiar with the main functions of the kpa-11 unit, the methodology for the production of uranium calibration standards was developed, and the calibration protocol was optimised, leading to reduced contribution of uncertainty in the final measurement result. Numerous measurements of uranium solutions and environmental waters were conducted in order to assess the measurement process, while optimising the recommended measurement protocols. Chemical treatment methods were developed and applied for liquid samples of more complex or polluted matrices. The methodology’s validity was verified by successfully participating in the almera 2009 intercomparison, while its efficacy was tested in an environmental radiation study conducted by the laboratory in rain water samples collected from a radiologically burdened location. Results were in agreement with a-spectroscopic analyses, verifying the method’s reliability, while reducing by tenfold the time required for obtaining a result. The methodology for determining uranium concentration in urine samples with the phosphorimetric apparatus was also developed. A chemical treatment method was adjusted and applied to urine samples of staff members of the laboratory, the uranium concentration of which was found within the icrp limits. The method’s validity was verified by successfully determining the uranium concentration of a urine sample from the procorad 2010 intercomparison. Finally, in order to reduce running costs of the kpa-11 unit, the possibility of using alternative analysis objects was examined. A complexant solution for phosphorescence protection was prepared from phosphoric acid that, despite its poorer complexing capabilities compared to its commercial counterpart, did not lack in accuracy, while it prolonged a calibration’s lifetime significantly.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2010

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Efstathopoulos, Aggelos
  • Ευσταθόπουλος, Άγγελος

Subjects

dc:subject × 18

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/23063

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Efstathopoulos, Aggelos; Ευσταθόπουλος, Άγγελος. Στοιχειακές και ισοτοπικές αναλύσεις ουρανίου σε υγρά δείγματα. National Technical University of Athens (NTUA), 2010. http://hdl.handle.net/10442/hedi/23063