Back to search

National and Kapodistrian University of Athens

Κατεργασία και τροποποίηση πολυμερικών υλικών για την κατασκευή και ενεργοποίηση με ηλεκτροδιαβροχή μικρορευστομηχανικών διατάξεων

Abstract

dc:description

In the present study, we investigated hydrophobic fluorocarbon plasma-deposited polymeric films with suitable properties for the realization of microfluidic devices where discrete biological (to be analyzed) fluidic droplets are transported on open surfaces or inside microchannels through electrowetting (contact angle modulation with voltage application). The fluorocarbon gas used for the deposition of the fluorocarbon films was c-C4F8 (octafluorocyclobutane), while the plasma conditions that provide films with optimized physical and chemical surface properties, by varying the plasma parameters, such as plasma power, substrate bias voltage and temperature, chamber pressure and fluorocarbon gas flow rate, were investigated. The substrates used were Si, SiO2 and Si3N4, while deposition (or etching) rates and deposited films thickness were investigated using in situ spectroscopic ellipsometry, which also provided the optical properties of the studied fluorocarbon films. The wettability (hydrophobicity/hydrophilicity) of plasma-treated substrates was studied using a contact angle measurement system. The surface roughness was measured by atomic force microscopy (AFM), while chemical composition of the plasma-deposited films was provided by X-ray Photoelectron Spectroscopy (XPS) and Fourier Transform Infrared Spectroscopy (FTIR). The physical (wettability, roughness, contact angle hysteresis) and chemical (composition) properties of plasma-deposited fluorocarbon films, in combination with a dielectric material (SiO2 or Si3N4) for improvement of dielectric properties, were correlated to their electrowetting behavior, initially with H2O and finally with protein solutions. Contact angle modulation with voltage application, contact angle reversibility after voltage removal, as well as possible protein adsorption on fluorocarbon surfaces, using fluorescent microscopy, were investigated. Furthermore, similar experiments were conducted for comparison using a commercial hydrophobic material commonly used in electrowetting applications, Teflon® AF (amorphous fluoropolymer), which was spin-coated on the dielectric material. Based on this study, we chose the appropriate conditions that provide hydrophobic fluorocarbon films that exhibit high hydrophobicity, small contact angle hysteresis, significant contact angle modulation with low voltage application, high contact angle reversibility after voltage removal, and negligible protein adsorption, while we fabricated an open microfluidic device baring hydrophobic fluorocarbon films, on which discrete droplets were transported through electrowetting. The use of FC plasma-deposited films for the actuation of protein solution droplets via electrowetting was realized for the first time in the literature. Comparison of these films with the commercial material gave comparable results. This outcome, along with the fact that plasmadeposited films present certain advantages compared to spin-coated commercial films, including thickness homogeneity, good adhesion and the ability to be deposited selectively, render these films appropriate hydrophobic materials for fabrication of microfluidic devices and actuation of biological solutions droplets using electrowetting. Finally, we developed a simple and fast method for the fabrication of biomolecular microarrays through selective molecular adsorption on hydrophilic SiO2 or Si3N4 patterns on hydrophobically modified Si substrate, by taking advantage the ability of fluorocarbon films to be selectively deposited on certain substrates versus others. The hydrophobic/hydrophilic patterning resulted from standard photolithography process and subsequent treatment in c-C4F8 plasma, where a hydrophobic fluorocarbon film was selectively deposited on Si, while at the same time the SiO2 or Si3N4 patterns were etched maintaining their hydrophilicity. The smallest protein spot size we have created so far is 750 nm. This method can be used for the fabrication of biomolecular microarrays with very small spot size, size that basically depends on the resolution of the lithographic process, increased spot density (higher than that commercially available), and increased signal to noise ratio due to elimination of adsorption on non-designated area.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2007

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Bayiati, Pinelopi
  • Μπαγιάτη, Πηνελόπη

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/23104

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Bayiati, Pinelopi; Μπαγιάτη, Πηνελόπη. Κατεργασία και τροποποίηση πολυμερικών υλικών για την κατασκευή και ενεργοποίηση με ηλεκτροδιαβροχή μικρορευστομηχανικών διατάξεων. National and Kapodistrian University of Athens, 2007. http://hdl.handle.net/10442/hedi/23104