National and Kapodistrian University of Athens
Αξιολόγηση εναλλακτικών τεχνικών για την ανάπτυξη νέων και βελτιωμένων μεθόδων προσδιορισμού φαρμάκων σε πλάσμα με την τεχνική της δίδυμης φασματομετρίας μαζών
Abstract
dc:descriptionIn the current study, alternative techniques of plasma samples pretreatment and analysis were examined, in order for new quantitative determination methods of pharmaceutical compounds to be developed by employing LC-MS/MS technique. The goal of the study was the increase of sensitivity of the analytical method and the reduction of the total time of the analytical procedure. All three general steps of a typical analytical method were studied, namely sample pretreatment, chromatographic separation and spectrometric determination. Alternative techniques application was examined for all of the steps mentioned above, aiming at the development of improved analytical methods. All methods developed were based on 96 well format profiles combined with the employment of two robotic liquid handling systems. In the first section of the study a method for the quantitative simultaneous determination of simvastatin and its hydroxyl-metabolite in human plasma by ESIMS/ MS was developed and fully validated. Pretreatment procedure employed 300 μL of plasma sample including a combined technique of ACN protein precipitation followed by a two-step extraction with MTBE. Protein precipitation step resulted in significant sensitivity increase as well as matrix effect limitation. Two-step extraction increased sensitivity as well compared to conventional one-step LLE allowing the quantitation of samples with a QL of 0.100 ng/mL. Combination of the two pretreatment techniques allowed the employment of the advantageous 96 format. The method developed included the shortest reported chromatographic runtime (1.9 min) and was successfully applied to the analysis of plasma samples of a bioequivalence study of a simvastatin formulation (40 mg). The current preatreatment protocol developed was proposed as a general model for analytical methods with significantly low quantitation limits, combined with high degree of high throughput maintenance for the whole procedure. In the second section of the study, ESI and APCI ion sources were evaluated and compared for anastrozole LC-MS/MS determination in plasma samples. The two sources application was studied in terms of sensitivity and matrix effect. In addition, Declustering Potential and Collision Energy influence in anastrozole determination sensitivity was evaluated and compared. As far as sample pretreatment is concerned, a protocol of ACN protein precipitation combined with an LLE step with MTBE was applied. Method sensitivity was highly increased due to the current protocol application, allowing the analysis of samples with a QL of 0.100 n/mL. APCIMS/ MS method developed included the shortest chromatographic run time reported (1.6 min) as well as the lowest plasma volume. Finally, analytical method was fully validated and applied to the bioequivalence study between two anastrozole formulations (1 mg). In the final section of the study, HILIC was compared to RPLC for the ESI-MS/MS determination of pharmaceutical compounds of medium-high polarity in plasma samples. The two techniques were compared in terms of sensitivity as well as high throughput and simplicity of pretreatment protocols. Retention mechanism of donepezil, cetirizine and loratadin was studied under the two chromatographic profiles. Next, two similar LLE methods for the quantitative determination of donepezil was developed, employing two different chromatographic protocols of HILIC and RPLC. The two methods were compared in terms of sensitivity. In addition, combination of direct injection after major sample preparation techniques (LLE, SPE and PP) with HILIC and RPLC ESI-MS/MS was evaluated. Compatibility of HILIC compared to RPLC-MS/MS was thus proven, in terms of sensitivity and high throughput of sample pretreatment procedure. Finally, the current study contributed to the broadening of the so far limited range of analyzable compounds with HILIC-MS/MS from highly polar to pharmaceutical compounds of medium polarity as well.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Apostolou, Constantinos
- Αποστόλου, Κωνσταντίνος
Subjects
dc:subject × 20- Δίδυμη φασματομετρία μαζών
- Υγροχρωματογραφία
- Πλάσμα
- Ευαισθησία αναλυτικής μεθόδου
- Ταχύτητα αναλυτικής μεθόδου
- Ιοντισμός με ηλεκτροψεκασμό
- Χημικός ιοντισμός σε συνθήκες ατμοσφαιρικής πίεσης
- Υγροσρωματογραφία υδρόφιλων αλληλεπιδράσεων
- Tandem mass spectrometry
- Liquid chromatorgaphy
- Plasma
- Analytical method sensitivity
- Analytical method throughput
- Electrospray ionization
- Atmospheric pressure chemical ionization
- Hydrophillic interaction liquid chromatography
- Ιατρική και Επιστήμες Υγείας
- Βασική Ιατρική
- Medical and Health Sciences
- Basic Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/23429