Back to search

National and Kapodistrian University of Athens

Βελτιστοποίηση συρραφής ρήξεων μηνίσκου με τη χρήση υλικών με μνήμη σχήματος: πειραματική μελέτη

Abstract

dc:description

Purpose: To evaluate the biomechanical results of meniscal repair in vitro by a Nitinol suture and compare them to Ethibond and Nylon. Methods: The six testing groups consisted of Nitinol, Ethibond and Nylon sutures (2-0 and 3-0). Forty-nine bovine menisci with a vertical longitudinal tear were repaired with one horizontal mattress suture and were fully immersed into a water bath, adjusted to a tensile testing machine. SMA were subjected to 7% elongation in a cold bath prior suturing, which was regained (suture contraction) after immersion of the repaired meniscus in the higher temperature bath of the testing machine. All specimens were subjected to tensile testing and Force/Displacement curves were obtained. Load to 5 mm gap, load to failure, tensile strength, stiffness and mode of failure for each suture group were recorded. Statistical analysis included analysis of variance with Bonferroni correction for the post hoc multiple comparisons. Results: Nylon sutures achieved the lowest scores in all measurements. SMA achieved better, but not significant, scores than Ethibond in load to 5 mm gap and stiffness. The 2-0 and 3-0 SMA suture repair demonstrated the highest average tensile strength and load to failure, with significant differences, being 31% and 50% stronger than Ethibond. Mode of failure included pulling-through the inner segment of meniscus and rupture of the suture at the knot. Conclusions: Nitinol is a promising meniscal suture material, providing better strength properties than conventional sutures and equivalent repair stiffness to Ethibond.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2008

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Lamprakis, Andreas
  • Λαμπράκης, Ανδρέας

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/23494

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Lamprakis, Andreas; Λαμπράκης, Ανδρέας. Βελτιστοποίηση συρραφής ρήξεων μηνίσκου με τη χρήση υλικών με μνήμη σχήματος: πειραματική μελέτη. National and Kapodistrian University of Athens, 2008. http://hdl.handle.net/10442/hedi/23494