National and Kapodistrian University of Athens
Εφαρμογές ιοντικής χρωματογραφίας στον προσδιορισμό οργανικών ιοντικών ενώσεων
Abstract
dc:descriptionFosetyl-Al [Aluminium tris (o-ethylphosphonate)], Glyphosate (N-phosphono-methyl glycine) and Glufosinate ammonium [Monoammonium 2-amino-4-(hydroxymethylphosphinyl) butanoate] are widely used pesticides in horticulture and agriculture. The aim of this study was the quantitative determination of all three pesticides, by High Performance Liquid Chromatography with evaporative light scattering and refractive index detection as well as Ion Chromatography with suppressed conductimetric detection. A novel method for the determination of Fosetyl-Al, Glyphosate and Glufosinate ammonium in pesticide formulations was developed, using anion exchange chromatography with conductimetric detection. The chromatographic method was based on an AS14 anion exchange column and a DX-100 ion chromatographic system. Fosetyl-Al, Glyphosate and Glufosinate ammonium are ionic compounds so they appear as ideal candidates for determination with ion chromatography and conductimetric detection. The objective of this study was the development of a fast, reliable and simple method for the analysis of the three pesticides. The optimized mobile phase for the elution of Fosetyl-Al, was 5 mM NaOH in an isocratic mode at a rate of 1.2 mL/min with a retention time of 6 min. The regression line was linear (concentration range 5-50 μg/mL) with a correlation coefficient of 0.999. Detection and quantitation limits were found to be 0.61 μg/mL and 1.9 μg/mL, respectively. The developed method was used for the separation of Fosetyl-Al from impurities (HPO42- and HPO32-) with Rs>4, while their determination was achieved with a different mobile phase (NaOH, 10 mM). In this case the detection limit for HPO42- and HPO32- were 0.28 and 0.51 μg/mL, respectively. The content of HPO42- and HPO32- in raw material were found to be 5.15% and 0.19%, respectively. The above method was used to determine the amount of Fosetyl-Al in four commercial pesticide formulations. No sample pretreatment was needed other than dilution with mobile phase. The accuracy of the proposed method was evaluated by recovery experiments with spiking diluted sample solutions. The recoveries obtained (96.4% - 101.7%) reveal good accuracy and repeatability (RSD= 2.25%). Further study of the matrix (excipients) effect on the determination was carried out by dilution experiments (determination in commercial pesticide formulations using a varying dilution factor D (Vinitial/ Vfinal) at three different levels). The correlation curve of the concentration found (in the diluted solution) versus D were linear ( r2 = 0.999) with a slope equal to the content of the formulation and a statistically zero intercept (proven by t-test). Similarly, the correlation curves for the content found versus D were linear as well with statistically zero slope. The results obtained reveal the absence of any constant or proportional determinate error from the excipients. The determination of Fosetyl-Al in soil and water samples was not achieved due to co-eluting peaks with the analyte and inability of isolation of Fosetyl-Al from the sample matrix. .................................................................................................................
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kakou, Aikaterini
- Κάκου, Αικατερίνη
Subjects
dc:subject × 13Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/23556