Back to search

National and Kapodistrian University of Athens

Δοσιμετρία στη στερεοτακτική ακτινοθεραπεία

Abstract

dc:description

The aim of Stereotactic Radiotherapy technique is to implement ionizing radiation in order to treat inoperative intracranial lesions. The requirement for high precision and high dose gradient makes stereotactic irradiation a credible method not only in multi fractionated Stereotactic Radiotherapy, but in single-fraction Radiosurgery, as well.The purpose of this thesis was the design and development of a complete Stereotactic Radiotherapy unit and its dosimetric evaluation. Dosimetry composes a major role in the establishment of any innovative part in the Radiotherapy procedure. Especially in small volume irradiation where high dose gradient and excellent dose delivery are mandatorÿ jio deliver the necessary dose to the target, while sparing the surrounding structures from potential danger. [ ■> | j 'Prototype stereotactic collimators were designed and constructed to be mounted to the wedge-tray of a linear accelerator. Mechanical limitations of the construction were taken into consideration before measuring the dosimetry parameters involved to the stereotactic technique. The measured dosimetric data were compared to corresponding calculated ones using Monte Carlo simulations. After the experimental data were certified, they were imported in the conventional treatment planning system to adapt a new, stereotactic specialized planning system.Very good agreement was found between the theoretically calculated data with Monte Carlo simulations and measured ones. This guarantees the manufacturing precision and effectiveness of the developed collimating cones and assures their locking system. An innovative method was implemented to simulate the prototype collimators into the treatment planning system, offering the ability to realize rotational therapy. Treatment planning optimization was realized by using gel dosimeters to correlate calculated and measured isodose distributions.Dose verification was accomplished by the use of an anthropoid head phantom, rotationally irradiated, including radiographic films to illustrate dose distributions different planes. The film-derived isodose distributions together with planned ones were plotted in the same graph, using proper software for image digitization, to make comparison feasible. Little variation was shown between the examined distributions verifying the adequate precision and reproducibility of the proposed stereotactic treatment.Other aspects of stereotactic dosimetry process were also investigated, such as the role and quality assurance of virtual wedge, to form a complete dosimetric evaluation program. Thus, the proposed auxiliary collimators form a simple, accurate, in terms of dose delivery, and mainly a cost effective method, which can be established in the future for intracranial lesions' irradiation.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2005

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Paschalis, Theodoros
  • Πασχάλης, Θεόδωρος

Subjects

dc:subject × 19

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/23571

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Paschalis, Theodoros; Πασχάλης, Θεόδωρος. Δοσιμετρία στη στερεοτακτική ακτινοθεραπεία. National and Kapodistrian University of Athens, 2005. http://hdl.handle.net/10442/hedi/23571