Aristotle University Of Thessaloniki (AUTH)
Ο πάσσαλος θεμελίωσης ως γεωεναλλάκτης: διερευνήσεις για τη θερμική του συμπεριφορά
Abstract
dc:descriptionSubject of the dissertation is the thermal performance of the cast in place Energy Piles (EPs). These are concrete foundation piles of large diameter, in which multiple branches of polyethylene pipes filled with a fluid are embodied. The aim is to thermally activate the piles themselves and the soil around them. Most commonly, the EPs are coupled to Heat Pumps, allowing a part of the building to be heated or cooled by using them as a ground heat exchanger. A methodology to compare the heat transfer efficiency of EPs with different design parameters is proposed. The methodology is to determine the basic design parameters of the EPs: the number of U Tubes, the type and dimensions of the pipes and the flow conditions in the pipes. It is based on the fact that the ranges of values of the thermal properties of the reinforced concrete and of the soil around them are the same. The methodology proposes EPs with different design to be compared by comparing the fluid temperature, under a constant heat injection rate (W per linear meter of pile’s length), considering a homogeneous infinite concrete - ground solid. Temperatures around the pipes are calculated by applying the Continuous Line Source Equation for each pipe, with a polynomial approximation of the exponential integral. The calculation period is the one just after the thermal influence between all the pipes has been developed and until the conductive heat transfer along the pile becomes significant. It is proved that the temperature at the axis of an EP of a given diameter does not depend on its design parameters. So, energy piles with different design parameters can be compared, the comparison based on the constant in time part of temperature difference between the fluid and that in the axis of the pile. The methodology is simple, easily applicable and closer to the real thermal behavior of the pile. By using it, useful findings on the thermal performance of EPs are resulted. The heat transfer in EPs along their length is examined also. Correlation functions between the mean temperature along the axis, the time after the emission start, the EP length and the emission radius are proposed. The finding is that short EPs with large diameters can receive higher thermal loads of long duration than the longer piles of smaller diameters. A survey for the thermal behavior of EPs is presented, given the fact that there is a significant difference between the thermal properties of the concrete and that of the surrounding soil. The survey is being carried out by means of the corresponding problem of heat diffusion in one dimension. According to the results can be seen that the thermal behavior of EPs under constant heat injection of short duration is determined by the thermal properties of the concrete. The thermal behavior of an EP under extra long term thermal loads is determined by the thermal properties of the surrounding soil. The thesis includes an Appendix and an extended summary in English
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2011
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Bozis, Dimitrios
- Μπόζης, Δημήτριος
Subjects
dc:subject × 20- Πάσσαλος γεωεναλλάκτης
- Γεωθερμικός πάσσαλος
- Γεωθερμική αντλία θερμότητας
- Βρόχοι σωλήνων
- Πάσσαλοι θεμελίωσης
- Γεωεναλλάκτης
- Γεωθερμία
- Εξίσωση γραμμικής εκπομπής θερμότητας
- Energy pile
- Pile heat exchanger
- Ground source heat pump
- U tubes
- Foundation piles
- Ground heat exchanger
- Geothermal energy
- Line source equation
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Μηχανολόγου Μηχανικού
- Engineering and Technology
- Mechanical Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/23574