National and Kapodistrian University of Athens
Συγκριτική μελέτη της υποξίας στον τοκετό μεταξύ καρδιοτοκογραφίας και του συνδυασμού υπολογιστικής καρδιοτοκογραφίας και παλμικής οξυμετρίας
Abstract
dc:descriptionThe successful management and outcome of labor depend mainly on the evaluation of fetal well-being, which is achieved by using modern biochemical and biophysical methods of fetal monitoring both during pregnancy and labor. With these methods, we try to determine directly or indirectly the degree of fetal oxygenation. It has been shown that fetal monitoring during labor contributes to a reduction in neonatal mortality and morbidity caused by inadequate oxygenation. This study compare classic cardiotocography (CTG) as the only method of intrapartum surveillance, with the combination of computerized CTG and fetal pulse oxymetry (FPO), as to whether they may provide prompt and accurate prediction of fetal hypoxia, whether they may change the perinatal outcome, and if they offer the possibility of reducing any unnecessary obstetrical intervention. For this purpose, 196 women were studied, which had normal singleton, full-term pregnancies in vertex presentation. The women were randomized into two groups: Group A included those who were monitored only by CTG throughout labor and delivery (n = 97) which was empirically evaluated using the criteria of the American College of Obstetricians-Gynecologists, and Group B included those who were monitored by both CTG, which was analyzed by computer using the Matching Pursuit algorithm, and by EPO throughout labor and delivery (n = 99). Then the two groups were compared in terms of perinatal outcome. After delivery, 1 cc of arterial blood was obtained from the umbilical cord with a heparinized syringe for the assessment of fetal acid-base balance. Biochemical parameters as the pH, the pO2, the pCO2, and base deficit (BDecf) were measured. The results were compared with the 1st and 5th minute Apgar Scores of the newborn. In conclusion, the application of FPO during labor and delivery is a reasonably reliable method for predicting fetal hypoxia and when combined with the CTG, its reliability rises. The objective evaluation of CTG recordings by computer using the Matching Pursuit algorithm, combined with the estimation of fetal arterial blood O2 saturation with the use of FPO, it appears that has sensitivity greater than 90% and specificity close to 80%, and therefore, can be used for prompt and objective diagnosis of fetal hypoxia during labor and delivery. The number of invasive deliveries with the indication of fetal hypoxia was greater in the group that had empirical interpretation of CTG recordings as the sole method of fetal surveillance, than in the group that had the combination of computerized CTG and FPO, and the difference was statistically significant. In these women of the first group who delivered invasively with the indication of fetal distress, only 27% were eventually confirmed by the biochemical parameters and Apgar Scores. It was estimated that the application of EPO during labor, could reduce by 39% any unnecessary obstetrical intervention. For the future, the analysis of fetal heart rate (FHR) will maintain its role as a key aspect of fetal surveillance. Today, the CTG should be considered as a screening tool. The potential of computers, may improve the gathering of information contained in the FHR and provide new ways of learning and education
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2009
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Hintipas, Elias
- Χιντιπάς, Ηλίας
Subjects
dc:subject × 13Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/23626